straddling the two pins labeled “NORMAL” which are nearest the front of the iScan board.
21)Remove this jumper from its current position by grabbing the top of the jumper and pulling directly away from the PC board.
22)Push the jumper onto the two pins closest to the rear of the iScan board, labeled
Modifying Sync-on-Green Jumper
Setting
23)To configure the unit to merge sync with Green, you should work with the jumper labeled
24)Remove this jumper and push onto the two pins closest to the rear of the iScan board, labeled
Modifying VCR Mode Jumper Setting
Jumper is on NORMAL pins
25)To enable the iScan Plus v2’s time base corrector, you will need to modify the setting of a jumper which is not labeled. See the diagram above for the location. A plastic jumper should already be straddling the two pins that are closest to the rear of the board.
26)Remove this jumper from its current position by grabbing the top of the jumper and pulling directly away from the PC board.
27)Push the jumper onto the two pins closest to the front of the board. Note that this is the opposite convention from the other two jumpers which are in NORMAL mode when on the two
Reassembling the iScan Plus v2
The iScan board sits in the bottom slot
with the metal enclosure. (See below).
30)Place the EMI gasket and the back panel over the connectors and make sure that it is flush with the sides of the housing.
31)Screw the two screws into the rear panel of the unit.
You may want to attach a note to the iScan Plus v2 specifying which internal setting you have changed.
28)Push the PC board back into the unit slowly, being careful that the bottom slots in the housing are used to guide the board and that the front LEDs appear through the front panel. Verify that the front panel switches protrude fully through the panel.
29)Replace the copper grounding clip so that it tucks between the power connector and the PC board and so that it makes contact
24