Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX user manual H. Fuel Filter, Trouble Shooting Guide

Models: RMC-KFA65TDLX, RMC-KFA120TDLX, RMC-KFA170TDLX RMC-KFA120TDLX, RMC-KFA170TDLX

1 12
Download 12 pages 25.3 Kb
Page 8
Image 8
NEVER LEAVE THE HEATER

NEVER LEAVE THE HEATER

 

NEVER LEAVE THE HEATER

 

UNATTENDED WHILE BURNING!

 

UNATTENDED WHILE BURNING!

 

 

 

 

 

H.) FUEL FILTER

10. TROUBLE SHOOTING GUIDE

CLEAN OR REPLACE TWICE A HEATING SEASON OR AS NEED.

-Remove upper shell(See 10 page).

-Remove Fan Blade(See 11 Page).

-Pull Fuel Line off from Fuel Filter Neck.

-Remove Fuel Filter.

-Wash Fuel Filter with clean kerosene and replace in tank.

-Attach Fuel Line to Fuel Filter Neck.

-Replace Fan Blade and Upper Shell.

I.) PUMP PRESSURE ADJUSTMENT

-Start Heater(See Operation, Page 8) and allow motor to reach full speed.

-Adjust Pump Pressure.(Using a Flat blade screwdriver)

Turn Relief Valve clockwise to increase pressure. Turn Relief Valve counter-clockwise to decrease pressure.

Set Pump pressure according to the chart below. -Stop Heater(See Operation, Page 8).

MODEL

PUMP PRESSURE

RMC-KFA65TDLX

3.5 psi

RMC-KFA120TDLX

4.5 psi

RMC-KFA170TDLX

6.5 psi

 

 

Figure 18. Removing Fuel Filter

Figure 19. Adjusting Pump Pressure

NOTE: USE ONLY ORIGINAL EQUIPMENT REPLACEMENT PARTS.

USE OF ALTERNATE OR THIRD PARTY COMPONENTS WILL VOID ANY WARRANTY AND MAY CAUSE UNSAFE OPERATING CONDITION.

13

14

Page 8
Image 8
Dyna-Glo RMC-KFA120TDLX, RMC-KFA170TDLX user manual H. Fuel Filter, Trouble Shooting Guide, I. Pump Pressure Adjustment