5. Remote Control Connector

figure 1:

 

figure 2:

pin assignment of the remote control plug

example for a remotely controlled application

1

ON/OFF (TOGGLE) INPUT

ON/OFF function of the supply output for the modules MODULE

 

 

OUT through the pulse contact to the negative potential. Only

 

 

functions when pin 11 carries an analogous supply voltage and

 

 

when the internal jumper J502 is set to “open”; can be used to

 

 

remotely switch the PA-system ON/OFF.

 

 

The external power-failure-recognition only functions, when the

 

 

needed supply-voltage is connected to pin 11 and when the internal

 

 

jumper J 502 is in place. It can also be used for controlling the

 

 

PA-installation whenever another phase fails. In that case, identical

 

 

functions are carried out, as if a failure in the mains supply of the

 

 

DPP 40xx would occur. Contact connected to ground is equivalent

 

 

with an ext. mains failure.

2

ON/OFF (MODULES) INPUT

ON function of the supply output for the modules MODULE OUT

 

 

through permanent contact to the negative potential. Only functions

 

 

when pin 10 carries an analogous supply voltage; can be used to

 

 

remotely switch the PA-system via the PROMATRIX System ON/OFF.

3

GND

Negative potential for the inputs 1 and 2; in case the internal supply

 

 

voltage is utilized for the remote control.

4

MAINS REMOTE ON OUTPUT

Control output for power amplifiers of the PROMATRIX SYSTEM

 

 

without network operation and for power amplifiers of the DEM

System; signals the switching-on command of the mains supply via contact to the ground potential.

5BATTERY REMOTE ON OUTPUT Control output for power amplifiers of the PROMATRIX SYSTEM without network operation and for power amplifiers of the DEM System; signals the switching-on command of the battery supply via contact to the ground potential.

6

POWER FAIL OUT OUTPUT

Signals the stable presence of the mains as well as internal 24 V

 

 

 

supply voltage via 24 V output voltage; internal resistance 1 kΩ.

7

DELAY OUTOUTPUT

Signals the PA-system’s “ready for operation” state via 24 V

 

 

 

output voltage and can be used to control alarm / gong / summing

 

 

 

modules of the DEM System.

8

GND

 

Negative Potential for the output 7.

9

+24V

OUTPUT

Supply output for the inputs 1 and 2; cannot be used for any

 

 

 

other purpose.

10

+24V

IN (MODULES) INPUT

Supply input for the MODULES input; has either to be connected

 

 

 

to pin 9 or needs +24 V supply from an external source.

11

+24V

IN (TOGGLE) INPUT

Supply input for the TOGGLE input; has either to be connected

 

 

 

to pin 9 or needs +24 V supply from an external source.