CONTROLS
LIMIT brief blinking indicates that the power amplifi er is operated at its limits.
SIGNAL indicates the presence of an input signal.
THERMAL lights, when the power amp’s output power is reduced to prevent thermal overload.
PROTECTION lights, when one of the power amp’s comprehensive protections against e.g. thermal overload, HF or DC at the output, and
The PROTECT LED lights for approximately 2 seconds during
Mains switch for powering the appliance on or off. With the power amplifi er being switched on, the mains switch is backlit. If, after switching the power on, the switch is not backlit, please fi rst check whether the mains cord is correctly connected. In case the cord has been connected correctly and the switch still fails to light (no function), please contact your specialist dealer.
MAINS FUSE
Under normal circumstance the mains fuse only blows in case of failure. Always use an identical type with the same current, voltage and blow characteristics when replacing the mains fuse. If the mains fuse blows more often, please contact your specialist dealer.
MAINS IN
Mains connector is carried out as
MAINS OUT
This PowerCon mains out socket allows the connection of additional
MADRAS cabinets, e.g. M15 or M18, using special cords (PC150 or
PC800).
To prevent mains n etwork overload, connecting more than three MADRAS cabinets to a single mains outlet
6