![](/images/new-backgrounds/1001149/114925x1.webp)
mandatory to perform any plugging or unplugging of microphone cables with the phantom power turned off. Also make sure, that the phantom power is turned off when utilizing microphones that are not meant to be operated with phantom power. The voltage that is present on pin 2 and pin 3 of the
17. input sensitivity switch (IN 1)
Setting this switch to its
18. input “IN 1"
This balanced input lets you either connect a
19. mains cord connector
This connector is meant for the connection of the supplied mains cord.
20. binding posts for the DC battery supply
These two binding posts allow the connection of an external 24 V DC power supply ( e. g. a 24 V DC battery). In this way continuous operation of the amplifier is maintained even during a power outage, since it is automatically switched to the DC power source.
NOTES
The amplifier is not capable of recharging the connected battery. Thus, it is recommended to have a suitable device at hand.
When the amplifier is operated on the DC power source, the nominal power handling capacity drops by approximately 20 %.
21. binding posts
22. binding post “COM”
The common terminal for the outputs (23) and (24).
13