• MC-MP-CE Spa Pack •
The Quick Reference Card provides a quick overview of your spa's main functions and the operations
accessible with your digital control pad. Note that some functions require the use of the K-4 keypad (10 keys). *
Starting Pump 1:
Press Pump 1 to turn Pump 1 on at low speed. Press a second time to turn Pump 1 to high speed. A third time turns Pump 1 off. A built-in timer automatically turns pump off after 20 min- utes, unless it has been manually deactivated.
The "Pump 1" indicator lights up when Pump 1 is on at high speed. It flashes when Pump 1 is on at low speed.
Starting Pump 2:
Dual-speed pump system:
Press Pump 2 to turn Pump 2 on at low speed. Press a second time to turn pump to high speed. A third time turns pump off.
Single-speed pump system:
Press Pump 2 to turn Pump 2 on. Press a second time to turn Pump 2 off.
In both cases, a built-in timer turns Pump 2 off after 20 minutes, unless it has been manually deactivated.
The "Pump 2" indicator lights up when Pump 2 is on. With a dual-speed pump,
it will flash when Pump 2 is on at low speed.
Turning the light on:
Two-intensity spa light:
Press Light key to turn light on at high intensity. Press a second time to turn light to low inten- sity. A third time turns light off.
One-intensity spa light:
Press Light key to turn light on. Press a second time to turn light off.
In both cases, a built-in timer turns light off after 2 hours, unless manually deactivated first.
The "Light" indicator is displayed when light is on at high intensity. It flashes when light is on at low intensity.
Fiber Box Option: If your spa has an optional fiber box, press Light key to turn fiber box (motor & light) on. Press a second time to turn fiber box motor off and leave light on. A third time turns both motor and light off. A built-in timer turns fiber box off after 2 hours, unless it has been manually deactivated. The "Light" indicator is displayed when fiber box light is on. It flashes when fiber box motor and light are on at the same time.
LED Light Option: If spa has an optional LED light, Press Light key to turn LED lights on.
To advance to the next color/display setting, press Light key twice. The LEDs will go off with the first press, then back on in the next setting with the second press. If the LEDs remain off for more than 5 sec., the color/ display sequence will reset and start back at the beginning the next time the Light key is pressed. Color/ display sequences are:
1• LEDs light up and slowly cycle through all six colors. The slow cycle restarts at the beginning and repeats.
2• LEDs light up and remain on in Aqua. 3• LEDs light up and remain on in Purple. 4• LEDs light up and remain on in Blue.
5• LEDs light up and remain on in Gold. 6• LEDs light up and remain on in Green. 7• LEDs light up and remain on in Red. 8• LEDs light up for 2 sec., flash off, then
flash on in the next color until all six colors have been displayed. The flashing cycle then repeats itself.
9• LEDs flash on/off quickly for a strobe light effect. A built-in timer turns lights off after 2 hours unless manually deactivated first.
The "Light" icon is displayed when LED light is on.
Starting the blower:
Press Blower to turn blower on at high speed. Press a second time to turn blower to low speed. A third time turns blower off. A built-in timer automatically turns blower off after
20 minutes, unless manually deactivated first.
The "Blower" indicator lights up when blower is on at high speed. It flashes when blower is on at low speed.
Automatic water heater start:
| Standby mode: |
Starting Pump 3: * | Press and hold Filter key for 5 seconds to turn |
the system down (i.e. to set it to Standby |
| mode) for 60 minutes. The display toggles |
Press Pump 3/Off to turn Pump 3 on. Press | between "SBY" message and the time re- |
a second time to turn Pump 3 off. A built-in | maining. All keys are then disabled, unless |
timer automatically turns pump off after | you press Filter key to reactivate the system |
20 minutes, unless manually deactivated first. | before the expiration of the 60-minute delay. |
Troubleshooting
When water temperature is 0.5˚C (1˚F) lower than the Set Point, the heater will automatically turn on until water temperature reaches Set Point plus 0.5˚C (1˚F).
The "Heater" indicator lights up when the heater is on. It flashes when there is a request for more heat but the heater has not yet started.
Note: The heater will not start if two pumps or more are running at high speed.
Setting water temperature:
Use Up or Down arrow key to regulate water temperature. The temperature setting will be displayed for 5 seconds to confirm your new selection.
The "Set Point" symbol indicates the
desired temperature, NOT the current water temperature!
Water temperature can be adjusted by 0.5˚C or 1˚F increments from 15 to 40˚C (59 to 104˚F).
Pumps have started up for one minute on several occasions and "Filter Cycle" icon is flashing.
Not a bug but a feature!
Our Smart Winter Mode protects your system from the cold by automatically turning pumps on for one minute several times a day to prevent water from freezing in pipes.
The display is flashing.
A power failure has occurred. Press any key to reset the system.
Water temperature is displayed.
Water temperature in the spa has reached 44˚C (112˚F).
Do not enter the water! Allow water to cool down. The system will reset au- tomatically when water reaches 43˚C (109˚F).
Call your dealer or service supplier if problem persists.
3 flashing dots are displayed.
A problem has been detected.
Do not enter the water! Check and open water valves. Clean filters if nec- essary. Check water level. Add water if needed.
Shut power off and power your spa up again to reset the system.