Earlex HV7000P, HV7000A Cleaning Instructions, Spray Applicator, Fluid TIP & Needle Type P

Models: HV7000A HV7000P

1 12
Download 12 pages 13.63 Kb
Page 6
Image 6

N0150 05/05.qxd 27/5/05 10:28 am Page 6

CLEANING INSTRUCTIONS

Remember to disconnect the unit from the mains power when undertaking any cleaning of the Spray Port.

THE SPRAY APPLICATOR MUST BE THOROUGHLY CLEANED IMMEDIATELY AFTER USE. IF THE PAINT DRIES INSIDE THE GUN, CLEANING WILL BECOME MUCH MORE DIFFICULT AND MAY RENDER THE GUN INOPERABLE. THIS IS NOT COVERED BY WARRANTY.

The spray applicator is the same as a paintbrush, if it is not cleaned it will go hard and can become useless. You must therefore clean this out after use.

SPRAY APPLICATOR

1.Remove the gun container.

2.Pour any leftover paint into its container so that it can be used for the future.

3.Pour a quantity of the respective thinner into container, shake the spray applicator lightly, reassemble the gun, then spray this liquid through the gun. Repeat this until the thinner being sprayed is coming through with

no traces of paint.

4.Clean any traces of paint off the outside of the spray applicator.

5.Clean the container Seal inside the spray applicator body for Type P or inside the spray applicator body for Type A.

FLUID TIP & NEEDLE (Type P)

8.

Remove Fluid Tip Seal (5)

 

 

1.

Unscrew Air Cap Ring (1)

9.

Remove Paint Container Seal (12)

10.

Place all of these items into a container and clean

2.

Remove the Air Cap (2)

 

them using a brush and clean thinners

3.

Completely remove Fluid Adjusting Screw (8)

 

11.

Clean the inside of the body of the gun

4.

Remove the Spring (7)

12.

Thoroughly dry these parts before reassembling

5.

Remove the Fluid Tip Needle (6) by gently pulling

13.

Grease the Gland (10)

 

the trigger

 

14.

Reassemble parts in reverse order

6.Remove Direction Plate noting the position of notches (3)

7.Remove the Fluid Tip (4)

It is recommended fitting the Fluid Tip (4) prior to the needle

FLUID TIP & NEEDLE (Type A)

 

 

1.

Remove the Air Cap Ring (1)

6.

Immerse all of the parts above in thinners & clean

2.

Remove the Air Cap (2)

 

them thoroughly using the cleaning kit supplied

3.

Remove Direction Plate & Spring Assembly (3)

 

with the gun.

4.

Unscrew Adjusting Screw (12) & pull out the

7.

Before refitting the Needle, dip its end into some

 

Needle (9) & Needle Spring (11).

 

vasaline. This will automatically lubricate the

5.

Use the spanner supplied to remove the Fluid Tip

 

gland washer as it is inserted.

 

(4) & Fluid Tip Seal (5)

8.

The external surfaces of the spray applicator can

 

 

 

be wiped clean with a cloth soaked in thinners.

NEVER DISPOSE OF PAINTS OR SOLVENTS INTO DRAINS. CONTACT YOUR LOCAL COUNCIL TO ARRANGE COLLECTION OR FOR DETAILS OF NEAREST REGISTERED DISPOSAL SITE.

TURBINE UNIT AND CARRIER STAND

The Turbine unit and the Carrier and Stand can be cleaned using a damp cloth and a little thinners to remove paint stains.

6

Page 6
Image 6
Earlex HV7000P, HV7000A Cleaning Instructions, Spray Applicator, Fluid TIP & Needle Type P, Fluid TIP & Needle Type a