9
6
7
8
6.RJ11 Phone/Fax Protection Connectors
7.USB Communication Port
The provided LanSafe monitoring and shutdown software can be automatically configured to save your files and shut down your computer in the event of a prolonged power outage.
Your personal computer can receive the status as utility power line, utility power failure, on battery and low battery by contact closure signals that are sent through the USB port.
8.Circuit Breaker (resetable)
The button protrudes out when an overload condition occurs. If the button protrudes out, then disconnect some
9.Power connector
10 Amp IEC to 10 Amp Australian input lead provided.
Battery Replacement procedure:
1.Batteries must be replaced with identical type.
2.Disconnect UPS system from power source
3.Open battery door.
4.Disconnect used battery. Connect new battery. (It is important that connectors be firmly attached to new batteries.
5.Close battery door.
6.Properly recycle used battery.
350VA and 500VA models
8 | UserÊs Manual |