Gain peace of mind with industry-leading warranty

and service plans.

We are so confident about the performance and reliability of the
Powerware 9155 and Powerware 9355 UPSs and battery systems
that we back them with extensive warranty and service plans.
Warranty coverage. Gain the peace of mind that comes with factory
warranty coverage (parts and labor, UPS and batteries) and rapid
response from certified support engineers.
Powerware 9155
• 2 year limited factory warranty
• 10 year pro-rated warranty
• $250,000 load protection guarantee
Powerware 9355
• 1 year Service Protection Plan
• 7 x 24 emergency response
• On-site start-up support (8 hours/day, 5 days/week)
• 3 year battery warranty
• 1 year eNotify remote monitoring
Service plans. Beyond the warranty period, service plans are avail-
able to match any need—from basic UPS and/or battery support to
all-inclusive packages with unique features, such as advanced
remote monitoring with trending, customized capacity planning
reports, and power protection audits. Add your choice of guaranteed
response times, and you can tailor just the right support package for
your needs.

From Eaton—a global leader in power quality solutions.

The culmination of 40 years of R&D excellence, the Powerware 9155
and Powerware 9355 UPSs deliver confidence, and ensure that your
organization’s critical electronics are protected by the most reliable,
efficient, and full-featured protection available.
Eaton is a global leader in power quality and management solu-
tions—the #1 manufacturer of UPSs above 5000 VA (Frost & Sullivan:
World UPS Markets, 2004). Eaton’s Power Quality Solutions Operation
is headquartered in Raleigh, North Carolina, U.S.
For more information on the Powerware 9155 and the new
Powerware 9355 UPS:
www.powerware.com
1-800-356-5794
MODEL SELECTION TABLE - POWERWARE 9155 UPS (8–15 kVA)
Power Unit
Rating2 Input & Output Output Dimensions Weight3
Order Number1 Description (kVA/W) Connection4 Receptacles H x W x D (in) (lb)
K408110000 PW9155 Model 8 - 32 Battery (2-high) 8kVA / 7.2kW Hardwired See PDM chart 32.2 x 12.0 x 32.0 352
K408120000 PW9155 Model 8 - 64 Battery (3-high) 8kVA / 7.2kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 590
K408130000 PW9155 Model 8 - 32 Battery with Transformer (3-high) 8kVA / 7.2kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 558
K410110000 PW9155 Model 10 - 32 Battery (2- high) 10kVA / 9kW Hardwired See PDM chart 32.2 x 12.0 x 32.0 352
K410120000 PW9155 Model 10 - 64 Battery (3- high) 10kVA / 9kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 590
K410130000 PW9155 Model 10 - 32 Battery with Transformer (3-high) 10kVA / 9kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 558
K412110000 PW9155 Model 12 - 32 Battery (2-high) 12kVA / 10.8kW Hardwired See PDM chart 32.2 x 12.0 x 32.0 352
K412120000 PW9155 Model 12 - 64 Battery (3-high) 12kVA / 10.8kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 590
K412130000 PW9155 Model 12 - 32 Battery with Transformer (3-high) 12kVA / 10.8kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 558
K415110000 PW9155 Model 15 - 32 Battery (2- high) 15kVA / 13.5kW Hardwired See PDM chart 32.2 x 12.0 x 32.0 352
K415120000 PW9155 Model 15 - 64 Battery (3- high) 15kVA / 13.5kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 590
K415130000 PW9155 Model 15 - 32 Battery with Transformer. (3- high) 15kVA / 13.5kW Hardwired See PDM chart 47.8 x 12.0 x 32.0 558
1. 50/60 Hz auto-sensing. All models can be used for frequency/phase conversion with derated 80% load, please refer to manual for details.
2. Input voltage 200–240V with neutral or with optional input isolation transformer. Output voltages are user-selectable 100/200, 110/220, 120/240 Vac 180° phase displacement, or 120/208, 127/220 Vac 120° phase displacement.
3. Weight is installed weight, add 47lbs (2-high models) or 50lbs (3-high models) to determine shipping weight.
4. An input neutral is required for all configurations unless the input isolation transformer is used.
MODEL SELECTION TABLE - POWERWARE 9355 UPS (10–15 kVA)
Power Unit
Rating2 Input & Output Battery Dimensions Weight3
Order Number1 Description (kVA/W) Voltages4 Backup5 H x W x D (in) (lb)
KA1011100000010 PW9355 with 32-Battery (2-high) 10 kVA / 9kW 208/208 8 32.2 x 12.8 x 33.5 373
KA1012100000010 PW9355 with 64-Battery (3-high) 10 kVA / 9kW 208/208 22 47.8 x 12.8 x 33.5 609
KA1011200000010 PW9355 with 32-Battery (2-high) 10 kVA / 9kW 220/2202 8 32.2 x 12.8 x 33.5 373
KA1012200000010 PW9355 with 64-Battery (3-high) 10 kVA / 9kW 220/2202 22 47.8 x 12.8 x 33.5 609
KA1011400000010 PW9355 with 32-Battery with Transformer (3-high) 10 kVA / 9kW 480/208 8 47.8 x 12.8 x 33.5 577
KA1011600000010 PW9355 with 32-Battery with Transformer (3-high) 10 kVA / 9kW 600/208 8 47.8 x 12.8 x 33.5 57
KA1511100000010 PW9355 with 32-Battery (2-high) 15 kVA / 13.5kW 208/208 4 32.2 x 12.8 x 33.5 373
KA1512100000010 PW9355 with 64-Battery (3-high) 15 kVA / 13.5kW 208/208 13 47.8 x 12.8 x 33.5 609
KA1511200000010 PW9355 with 32-Battery (2-high) 15 kVA / 13.5kW 220/2202 4 32.2 x 12.8 x 33.5 373
KA1512200000010 PW9355 with 64-Battery (3-high) 15 kVA / 13.5kW 220/2202 13 47.8 x 12.8 x 33.5 609
KA1511400000010 PW9355 with 32-Battery with Transformer (3-high) 15 kVA / 13.5kW 480/208 4 47.8 x 12.8 x 33.5 577
KA1511600000010 PW9355 with 32-Battery with Transformer (3-high) 15 kVA / 13.5kW 600/208 4 47.8 x 12.8 x 33.5 577
1. 50/60 Hz auto-sensing.
2. 220V units are wye connected 220/127V input and 220/127V output, 3-phase, 4-wire plus ground.
3. Weight is installed weight, add 47 pounds (for 2-high models) or 50 pounds (for 3-high models) to determine shipping weight.
4. An input neutral is required for all configurations unless the input isolation transformer is used.
5. Internal battery, full load.
Powerware 9155 and Powerware 9355 at-a-glance