Technical

Specifications

Rating

40 kVA

60 kVA

80 kVA

100 kVA

120 kVA

160 kVA

 

9390-40-N

9390-60-U

9390-80-N

9390-100-U

9390-120-N

9390-160-N

Part number

9390-BAT10-40x55Ah

9390-BAT10-40x55Ah

9390-BAT10-40x55Ah

 

9390-120-U

 

9390-BAT10-40x67Ah

9390-BAT10-40x67Ah

9390-BAT10-40x67Ah 9390-BAT10-40x67Ah

9390-BAT10-40x67Ah 9390-BAT10-40x67Ah

 

 

9390-BAT10-40x125Ah

9390-BAT10-40x125Ah

9390-BAT10-40x125Ah 9390-BAT10-40x125Ah

9390-BAT10-40x125Ah 9390-BAT10-40x125Ah

Capacity (kVA/kW)

40/36

60/54

80/72

100/90

120/108

160/144

Dimensions WxHxD (mm)

519x1872x804

519x1872x804

519x1872x804

900x1872x804

900x1872x804

900x1872x804

Weight (kg)

 

 

 

 

 

 

UPS

257

313

313

480

480/530

530

9390-BAT10-40x55 Ah

1270

 

 

 

 

 

9390-BAT10-40x67 Ah

1430

 

 

 

 

 

9390-BAT10-40x125 Ah

2350

 

 

 

 

 

Input connection

Dual input, hardwired

 

 

 

 

 

Output connection

Hardwired

 

 

 

 

 

Typical runtime

 

 

 

 

 

 

UPS+1xBAT 55 Ah

30 min

17 min

10 min

8 min

6 min

UPS+1xBAT 67 Ah

39 min

21 min

15 min

12 min

10 min

UPS+1xBAT 125 Ah

87 min

53 min

36 min

27 min

20 min

12 min

Operational

 

 

 

 

 

 

Nominal input voltage (Vac)

220/380, 230/400, 240/415 VAC 50/60 Hz

 

 

 

 

Input voltage range

-15%, +10% from nominal at 100% load

 

 

 

 

Operating frequency

50 Hz or 60 Hz (45-65 Hz)

 

 

 

 

Input power factor

0,99

 

 

 

 

 

Input current distortion

< 5% THDi typical

 

 

 

 

 

Nominal output voltage

220/380, 230/400, 240/415 VAC

 

 

 

 

Output voltage regulation

±1% static, ±5% dynamic at 10% to 90% load change, < 1 ms recovery time

 

 

 

101-110% for 10 min

 

 

 

 

 

Overload capacity

111-125% for 1 min

 

 

 

 

 

126-150% for 10 sec

 

 

 

 

 

 

 

 

 

 

 

 

1000% for one cycle (bypass)

 

 

 

 

Efficiency

up to 94%

 

 

 

 

 

User interface

 

 

 

 

 

 

LCD display

Graphical LCD with blue backlight

 

 

 

 

LED

4 status indicators

 

 

 

 

 

Standard communication

(2 or 4) x XSlot, 1 x relay contact,

 

 

 

 

ports

1 x emergency power-off input, 2 x environmental inputs

 

 

 

 

External battery cabinets and racks,

 

 

 

 

Optional

Isolation transformer, System Parallel Cabinets;

 

 

 

 

XSlot: SNMP/Web/HUB, ModBus/JBus, Relay, Hot Sync cards

 

 

 

Environmental

 

 

 

 

 

 

Operating temperature

0°C to +40°C, +45°C with 7,5% derating, batteries max +25°C

 

 

 

Storage temperature

-15°C to +45°C

 

 

 

 

 

Altitude

< 1500 m

 

 

 

 

 

Audible noise at 1 metre

65 dB(A) 40-80 kVA

 

 

 

 

 

70 dB(A) 100-160 kVA

 

 

 

 

 

 

 

 

 

 

 

Certification

 

 

 

 

 

 

Quality

ISO 9001 : 2000, ISO 14001 : 1996

 

 

 

 

Markings

CE, GOST

 

 

 

 

 

Safety

IEC 62040-1-1, IEC 60950, EN 62040-1-1

 

 

 

 

EMC

EN 50091-2

 

 

 

 

 

7

Page 7
Image 7
Eaton Electrical 9390 manual Technical Specifications, Rating 40 kVA 60 kVA 80 kVA 100 kVA 120 kVA 160 kVA

9390 specifications

The Eaton Electrical 9390 UPS (Uninterruptible Power Supply) is designed to provide high-density power protection in critical applications. Featuring a robust architecture, the 9390 is engineered to deliver reliability and efficiency for mission-critical environments.

One of the standout features of the Eaton 9390 is its modular design, which allows for scalable power configuration. The system ranges from 40 to 750 kVA, making it suitable for various applications, from small server rooms to large data centers. This flexibility ensures that organizations can tailor their power solutions to meet specific needs while providing room for future growth.

The 9390 incorporates advanced double-conversion Online technology, ensuring that connected equipment receives clean and stable power regardless of input fluctuations. This is critical for protecting sensitive electronics from power surges, spikes, and outages that could otherwise lead to equipment failure or data loss.

Energy efficiency is another hallmark of the Eaton 9390 series. With an impressive operating efficiency of up to 94% at full load in double-conversion mode and even higher in energy-saving ECO mode, the 9390 minimizes energy loss and reduces operational costs. This efficiency not only benefits the bottom line but also aligns with sustainability initiatives by reducing the carbon footprint of power systems.

The UPS is equipped with multifunctional LCD displays that provide real-time information about the power status, battery health, and load conditions. Enhanced monitoring and management capabilities are also available through Eaton’s Intelligent Power Software, allowing users to remotely manage and monitor the UPS, ensuring optimal performance and uptime.

Another key characteristic of the Eaton 9390 is its superior battery management system. It features advanced battery health monitoring, which extends battery life and optimizes the charging process. This proactive approach dramatically reduces the risk of battery failures during critical moments, ensuring consistent power delivery.

Additionally, the Eaton 9390 includes various connectivity options, enabling integration with building management systems and offering seamless communication with existing infrastructure. This adaptability makes it a perfect fit for diverse environments, including healthcare, finance, telecommunications, and manufacturing.

In conclusion, the Eaton Electrical 9390 stands out as a premium UPS solution that combines efficiency, scalability, and advanced technologies. Its comprehensive features make it ideal for organizations seeking reliable and robust power protection for their mission-critical operations.