Technical Specfications2
UPS Rating (0.9 power factor)
kVA | 225 | 275 | 550 |
|
kW | 202 | 250 | 500 |
|
General Characteristics |
|
|
|
|
Efficiency | Up to 95% |
|
| |
Parallel Capability | Up to 3 modules, 550 kVA maximum | |||
Audible Noise | < 65dBA @ 1 meter |
| ||
Altitude (max) | 2000m at 40ºC (104ºF) |
| ||
N+1 Redundancy Capable | Yes |
|
|
|
Field Upgradeable | Yes, 275 kVA increments |
| ||
System Bypass Module | Included |
|
| |
Input Characteristics |
|
|
|
|
Voltage | 480V standard; 208V and 600V with isolation | |||
| transformer option |
| ||
Voltage Range | +10% / |
| ||
Frequency Range |
|
| ||
Power Factor | 0.99 (minimum) |
| ||
Input Current Distortion | <3% (no input filter required) | |||
Soft Start Capability | Yes |
|
|
|
Internal Backfeed | Yes |
|
|
|
Protection |
|
|
|
|
Output Characteristics |
|
|
|
|
Voltage | 480V standard; 208V and 600V with isolation | |||
| transformer option |
| ||
Regulation | ±1% |
|
|
|
Inverter | PWM with IGBT switching |
| ||
Voltage THD | <2% (100% linear load); <5% | |||
Load Power Factor Range | Up to a .9 power factor leading without | |||
Battery |
|
|
|
|
Battery Types | VRLA, AGM, Gel, Wet |
| ||
Battery Voltage | 480V |
|
|
|
Temperature Compensation | Optional |
|
| |
Charging Method | Advanced Battery Management technology | |||
Dimensions & Weights |
|
|
|
|
225 kVA, 275 kVA | 52.4”w x 34.3”d x 73.7”h | 1786 lb. | ||
225 kVA redundant, | 73.7”w x 34.3”d x 73.7”h | 2875 lb. | ||
275 kVA redundant |
|
|
|
|
550 kVA | 73.7”w x 34.3”d x 73.7”h | 2977 lb. | ||
550 kVA redundant | 95.0”w x 34.3”d x 73.7”h | 4153 lb. | ||
Field upgrade module, | 21.3”w x 34.3”d x 73.7”h | 1176 lb | ||
225 or 275 kVA |
|
|
|
|
Powerware®
Uninterruptible Power System (UPS)
225 to 825 KVA
User Benefits
Control Panel (LCD) | 8 lines x 40 characters |
Battery Startup | Standard |
|
|
Frequency Conversion | Standard |
Remote Display Panel | Optional |
Standard | |
|
|
Building Alarm Inputs | 6 (galvanic isolated) |
Serviceability |
|
Back/Side Against Wall | Standard |
Installation |
|
|
|
Options
External Maintenance Bypass
Powerware PDU, RPP, and STS
Isolation Transformer
Output Transformer
Maintenance Bypass Module
Certifications
Safety | UL1778, cUL |
|
|
EMC | FCC Class, A |
Surge | ANSI C62, 41 Cat, A&B |
eNotify Remote Monitoring
24x7 remote monitoring of 43 UPS and battery alarms, daily heartbeat check and monthly report ConnectUPS Web/SNMP/xHub card
Communications
Software Compatibility - PowerVision®, LanSafe®, FORESEER® , Power Xpert Communication Cards - Standard system includes one ConnectUPS Web/SNMP card with an Environmental Monitoring Probe. Four communication bays standard.
The following connectivity options can be installed at any time:
-ConnectUPS Web/SNMP/xHub
-Modus Card
-Relay Interface Card (Use for AS400s)
-Industrial Relay Card (5A@120V)
-Hot Sync CAN Bridge Card provides CAN communications, isolated
-Environmental Monitoring Probe (EMP)3
Remote Inputs/Outputs - Six building alarms inputs and one summary alarm contact (5A@120V) standard
Remote Panel - Eight backlit status indicator lamps plus an audible horn3
2. Due to continuing improvements, specifications are subject to change without notice.
3. Requires the ConnectUPS Web/SNMP/xHub card.
Europe/Middle East/Africa | Asia Pacific |
Denmark: 45.3686.7910 | Australia/NZ: 61.2.9693.9366 |
Finland: 358.94.52.661 | China: 86.21.6361.5599 |
France: 33.1.6012.7400 | HK/Korea/Taiwan: 852.2745.6682 |
Germany: 49.7841.666.0 | India: 91.11.2649.9414 to 18 |
Italy: 39.02.66.04.05.40 | Singapore/SEA: 65.6825.1668 |
Norway: 47.23.03.65.50 | Powerware, PowerVision, FORESEER, Power |
Sweden: 46.8.598.940.00 | |
United Kingdom: 44.1753.608.700 | Xpert, LanSafe, and ABM are trademarks of |
| Eaton Electrical Inc. |
| © 2007 Eaton Corporation |
| All Rights Reserved |
| Printed in USA |
| 9395FXA |
| March 2007 |
For additional information, please call