POWER BLOWER

OPERATOR'S MANUAL 11

IMPORTANT

Recoil starter: Use short pulls - only 45 ~ 60 cm (18 ~ 24 in.) of rope for starting. Do not allow the rope to snap back in. Always hold the unit firmly.

5.Recoil Starter

Place the unit on a flat, clear area. Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle/rope (E) until engine fires(5~6pullsmaximum).

6.After engine fires (or 5 ~ 6 pulls), move choke lever (C) to Run

( ) position and pull recoil starter handle/rope until engine starts and runs. Allow unit to warm up at idle for several minutes.

NOTE

If engine does not start with choke in “Run” position after 5 pulls, repeat instructions.

7.After engine warm up, gradually depress throttle trigger to increase engine RPM to operating speed.

E

C

STARTING WARM ENGINE

A

 

The starting procedure is the same as Cold Start except DO NOT close

 

the choke.

B

1.Stop Switch

Move stop switch button (A) away from the STOP position.

2.Throttle Position Lever

Move throttle position lever (B) forward to idle position.

3.Purge Bulb

Pump purge bulb (D) until fuel is visible and flows freely in the clear fuel tank return line. Pump bulb an additional 4 or 5 times.

4.Recoil Starter

Place the unit on a flat, clear area. Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle/rope (E) until engine

fires.

D

 

IMPORTANT

Recoil starter: Use short pulls - only 45 ~ 60 cm (18 ~ 24 in.) of rope for starting. Do not allow the rope to snap back in. Always hold the unit firmly.

NOTE

If engine does not start after 5 pulls, use Cold Start Procedure.

E