OPERATION

SRM-225

 

 

Move stop switch button (A) forward away from the STOP position.

2.Purge Bulb

Pump purge bulb (C) until fuel is visible in the “Clear” fuel return line. Pump bulb an additional 4 or 5 times.

C

3.Recoil Starter

Lay the unit on a flat area and keep movable attachment parts clear of all obstacles. Firmly grip throttle handle and throttle trigger lockout with left hand. Rapidly pull recoil starter handle/rope (D) until engine fires.

Note: If engine does not start after 5 pulls, use Cold Start

Procedure.

D

Stopping Engine

1. Throttle

A

Release throttle trigger and allow engine to return to idle before shutting off engine.

2.Stop Switch

Move stop switch button (A) backward to STOP position.

If engine does not stop when stop switch is moved to STOP position, close choke - COLD START position - to stall

engine. Have your ECHO dealer repair stop switch before using unit again.