7.2. Charging station

7.2. Charging station

The main switch for the charging station is located on the back of the unit. After switching on the handlamp, the charging process begins immediately. When charging is completed, the unit auto- matically reverts to trickle charge mode.

The LED indicates the following operating status:

Constant red:

no handlamp / contact

Constant green:

charging in process

Shortly before transition

 

to trickle charging:

constant green and flashing red

Constant red and green:

trickle charging

The batteries must be fully recharged at least once every 6 months.

Please note: only use ECOM charging equipment when charging ECOM handlamps.

Ambient temperature Ta: +10…+25 deg C.

Only operate in dry, well-ventilated rooms, outside of the Ex- hazardous area.

There are two different types of charging stations available for the H-251 A.

7.2.1. C – 251 HV

This charging station is designed for a supply voltage of 220-240 Volts AC with 50-60 Hz. A voltage of 100-120 AC Volts can be switched manually to 50-60Hz.

90% battery charging capacity is reached after 6-7 hours. After approximately 9 hours of charging, the battery should be completely recharged.

WARNING - an incorrect voltage can damage the equipment, therefore please take care to ensure that the correct voltage is selected.