3)Wall Installation

a)Make sure the exhaust hose is properly installed onto the portable air conditioner as described above.

b)Make a hole of 5 1/8” diameter in your wall.

c)Position the portable air conditioner near the hole.

d)Feed as much exhaust hose as is needed through the hole.

Notes:

Be sure to cover the hole when it is not being used by the portable air conditioner.

Be sure to have a qualified person make the hole to avoid the possibility of injury or of unintended damage to your room.

Operation

1) Control Panel

Power I ndi cat or

POWER

WATER FULL

Fan Speed

Di spl ay Li ght

Wat er Ful l I ndi cat or

Set t i ng Temper at ur e Di spl ay

Oper at i on Mode Di spl ay Li ght

Ti mer Set But t on

Fan Speed Set

But t on

HI GH

MED FAN

LOW

COOL

DRY

MODE

Temper at ur e But t on

FAN

Ti mer I ndi cat or

UP DOWN

Mode Set But t on

TIMER

FAN MODE

ON/OFF

ON/ OFF But t on

1) ON/OFF : On/Off Button Turns the unit on or off.

MODE

2):Mode Button

Selects the mode: Dehumidifying, Cooling, or Fan-only.

3)FAN :Fan Speed Button

Switches between low and high fan speeds.