10

Front and rear panel

fig.front

4. Input/output level indicators

These LEDs light according to the level of the signals that are being input via the combo

input jacks (1)

and
WAVE OUT 1/2 (in the case of WDM,

OUTPUT 1

see p. 22). (see block diagram

front cover)
To adjust the input level, stop playback of the sound from your computer.

5. Sync indicator

When the

digital input switch (6)

is on, this indicator shows the status of synchronization with a digital
device connected to the

digital input connector (7)

. (external synchronization mode)

6. Digital input switch

If you want to record a digital input, turn this on ( pressed inward). This lets the FA-101 synchronize to an
external digital device connected to the

digital input connector (7)

.

7. Digital input connector (optical)

Use this when you want to input a digital audio signal from a CD/MD/DAT or similar device.
The signal input to the digital input connector is input as

INPUT 9

and

10

(in the case of WDM,

INPUT 5

see p. 22).
If you want to record this digital input signal, turn on the

digital input switch (6)

.
You must input a signal of the same sampling frequency as that selected by the

sample rate select switch
(9)

.

8. Digital output connector (optical)

Use this when you want to digitally connect an audio device, such as an MD or DAT unit.
The digital signal sent from the

digital output connector

is output as

OUTPUT 9

and

10

(in the case of
WDM,

OUTPUT 5

see p. 22).

When functioning as input
level indicators

The red LED will light if the sound distorts. Use the

input level
knobs (2)

to adjust the input level so that the red LED does not
light.

When functioning as output
level indicators

The red LED will light, but the sound is not distorting.
* When operating at 192 kHz, the indicator will light only for input;
it will not light for output.

Lit green

Synchronized correctly.

Blinking green

Not synchronized. Check that your digital device is correctly connected to the
digital input connector.
Also make sure that the connected digital device is set to the same sampling fre-
quency as that selected by the FA-101’s

sample rate select switch (9)

.
12
4
4
78 956 10 11 15121314316
FA-101_e.book 10ページ 2005年11月24日 木曜日 午後1時25分