B15584-R0-225EN&220EN-U&C 6/9/07 8:13 AM Page 9

Table B shows how the CO Alarm reacts to different levels of CO gas and exposure time. At higher levels of CO the alarm turns on sooner. The rate of flashing of the red light indicates the level of CO.

Table B: CO Alarm Response

CO Level

Red

Horn On

ppm

Alarm Light

within

0 ppm

Off *

Off

50ppm

1 Flash / 2

Seconds

60 to 90 minutes

100 ppm

4 Flashes / 2

Second

10 to 40 minutes

300 ppm

8 Flashes /

2

Second

3 minutes

*unless it has been in alarm (see CO Alarm Memory below)

If your CO Alarm sounds follow the instructions on page 4.

When ventilation is provided by leaving the window and doors open, the CO build up may have dissipated by the time help arrives and the alarm may have stopped sounding. Although your problem may appear temporarily solved it is crucial that the source of the CO is determined and appropriate repairs made.

NEVER IGNORE THE ALARM.

Pre-Alarm:When the alarm detects over 50ppm CO the red light flashes every 2 seconds. This helps locate CO leaks, as the unit gives an indication straight away.

9

Page 9
Image 9
Ei Electronics Ei220EN manual Never Ignore the Alarm

Ei220EN specifications

The Ei Electronics Ei220EN is an advanced smoke and heat detector designed to provide enhanced safety and peace of mind in residential and commercial buildings. Incorporating state-of-the-art technologies, this device offers reliable performance and is engineered to detect both smoke and rising temperatures, ensuring comprehensive fire protection.

One of the standout features of the Ei220EN is its dual sensor technology, which combines both photoelectric and heat detection. The photoelectric sensor is adept at identifying smoldering fires that produce a significant amount of smoke, while the heat sensor excels in detecting rapid temperature increases indicative of flaming fires. This dual approach significantly reduces the potential of false alarms caused by common household activities, such as cooking or steam from showers.

The Ei220EN is equipped with a built-in 230V power supply, offering continuous operation without the need for frequent battery replacements. In the case of a power failure, a 10-year rechargeable lithium battery serves as a backup, ensuring that the detector remains operational during emergencies. This feature provides users with confidence that their premises are protected around the clock.

This smoke and heat detector also boasts a large, easy-to-read LED indicator, which shows the status of the device. During normal operation, the indicator glows green, while it turns red in the event of an alarm. Additionally, a test button allows users to easily check the functionality of the device, ensuring that it is in working order.

Another notable characteristic is the Ei220EN's ability to interconnect with up to 12 other Ei alarms, enhancing safety throughout large homes or commercial spaces. In the event of an alarm, all interconnected units will sound, creating a robust alert system that increases the chances of early detection and response to a fire.

The Ei220EN also features a low-profile design that allows for easy installation on walls or ceilings, blending seamlessly with various architectural styles. Constructed from durable materials, it is built to withstand various environmental conditions, making it suitable for different settings, whether residential or commercial.

Overall, the Ei Electronics Ei220EN smoke and heat detector is a vital component in any fire safety strategy. With its advanced dual sensor technology, reliable power source, user-friendly features, and interconnectivity options, it delivers dependable and effective protection against the dangers of fire, ensuring the safety of all occupants.