Model Ei3105RF Optical
Technical Specification
Sensor | Optical, uses light scatter from |
| smoke |
Sensitivity: | Complies with BS 5446 Part 1: |
| 2000 |
Automatic | Smoke Chamber is tested every 40 |
| Sec. and unit beeps (without LED |
| flash) if it is degraded. |
Supply Voltage: | 9V alkaline battery |
RF Range: | 150 meters (min) free space |
RF Visual Indicator: | Amber light flashes continuously |
| for 1.5 to 3.5 seconds while |
| transmitting RF signal |
RF Frequency: | 868.499MHZ (1% duty cycle) |
RF Power: | +5dBM |
Dimensions: | 140mm x 120mm x 45mm |
Weight: | 220g |
Red light flashes every 40 seconds | |
Alarm: | Electronic Piezoelectric horn |
Alarm Sound Output: | 85dB (minimum) at 3m |
Alarm Status: | Red LED flashes every second on |
| unit sensing fire |
Temperature Range: | 00 to 400 C |
Humidity Range: | 15% to 95% Relative Humidity |
Interconnect: | Up to 12 RadioLINK products |
Plastic material: | UL94HB flame retardant |
Warranty: | 5 year (limited) warranty |
Approvals: | Kitemarked to BS EN 14604: 2005, |
| CE Approved |
Specifications are subject to change
Installation & Placement
Place the alarm on the ceiling/wall and mark the screw holes. Drill with a suitable drill bit, insert the screw plugs and screw the alarm into position. Simply connect the battery on the alarm and slide into position on the mounting plate.
The RF alarms should be house coded to prevent possible interference from neighbouring installations – see instructions for more details.
Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of areas of “dead air” close to corners of rooms and apexes of ceilings, which could result in the prevention of smoke reaching the smoke detector
House Code Procedure
1.Connect the battery
2.Press the house code switch until the amber light turns on and then release
3.Similarly, place other alarms into house code mode
4.Check that the number of amber flashes (on each alarm) corresponds to the number of alarms in your system
5.Remove all alarms from house code
6.Button test each alarm to check your system
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. eielectronics@eiltd.ie
Web: www.eielectronics.com
E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice. | Ei3105RF DataSht RevB |