Ei Electronics Ei 156TLR manual Technical Specification, Model Ei156TLR Optical

Models: Ei 156TLR

1 2
Download 2 pages 41.07 Kb
Page 2
Image 2
Model Ei156TLR Optical

Model Ei156TLR Optical

Technical Specification

SensorOptical, uses light scatter from

smoke

Sensitivity:

Complies with BS 5446 Part 1:

 

2000

Source:

Contains no radioactive material

Airspeed:

Essentially immune to the effect

 

of airspeed.

Button Test:

Simulates the effect of smoke and

 

checks chamber, electronics and

 

horn.

Ambient Light:

Chamber housing design and

 

compensation overcomes

 

problems with stray light.

Automatic Self-Test:

Smoke Chamber is tested every 40

 

Sec. and unit beeps (without LED

 

flash) if it is degraded.

Insect Screen:

Prevents insects or debris entering

 

chamber (1.00mm mesh size)

Supply Voltage:

230V AC

Battery back up:

Rechargeable lithium cells

Power-On Indicator:

Continuous green LED

Alarm:

Electronic Piezoelectric horn

Alarm Sound Output:

85dB (minimum) at 3m

Alarm Status:

Red LED flashes every second on

 

unit sensing fire

Temperature Range:

0° to 40°C

Humidity Range:

15% to 95% Relative Humidity

Remote Control:

Ei152, Ei159 or MCP400

Interconnect:

Up to 12 interconnected

 

Ei150/151TLR/154TL/155/156TLH/

 

156TLR smoke or heat alarms,

 

along with an EI158 relay base

Fixing:

Screw fixings supplied

Plastic material:

UL94VO flame retardant

Dimensions:

140mm x 120mm x 46mm

Weight:

230g

Warranty:

5 year (limited) warranty

Approvals:

Kitemarked to BS EN 14604:2005,

 

CE Approved

Specifications are subject to change

Installation & Placement

Wiring for Interconnected Alarms

Be very careful about correctly wiring the alarms as mixing Live and Neutral will blow/damage interconnected alarms.

Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of areas of “dead air” close to corners of rooms and apexes of ceilings, which could result in the prevention of smoke reaching the smoke detector

Please consult instruction booklet for specific installation details

Important Precaution:

Do not install the actual smoke/heat alarm itself in new or renovated buildings until all work is completed (including floor coverings) and the building has been fully cleaned. The wiring can be installed when appropriate. (Excessive dust and debris from building work can contaminate the smoke chamber and cause problems, and it will also invalidate the guarantee). If it must be installed, cover it completely, particularly around the edges, with a dust cover (eg. a plastic bag), until all cleaning is finished.. Connect wires to the unit as in wiring diagram. All wiring must comply with local codes.

Shannon Free Zone, Shannon, Co. Clare, Ireland.

Ph.+353 61 471277 Fx.+353 61 471053

Email. eielectronics@eiltd.ie

Web: www.eielectronics.com

E & OE As our policy is one of continuous product development, we reserve the right to alter product details without prior notice.

Ei156TLR DataSht RevB

Page 2
Image 2
Ei Electronics Ei 156TLR manual Technical Specification, Model Ei156TLR Optical, Installation & Placement