28
5. Referenz
Pin-Belegung
•DVI-D-Anschluss
12345678
9
1011 12 13 14 15 16
1920 211718 2223 24
SIGNAL1 : Gilt für DualLink
Pin No. Signal Pin No. Signal Pin No. Signal
1T.M.D.S. Data 2- 9T.M.D.S. Data1- 17 T.M.D.S. Data0-
2T.M.D.S. Data 2+ 10 T.M.D.S. Data1+ 18 T.M.D.S. Data0+
3T.M.D.S. Data2/4 Shield 11 T.M.D.S. Data1/3 Shield 19 T.M.D.S. Data0/5 Shield
4T.M.D.S. Data 4- 12 T.M.D.S. Data 3- 20 T.M.D.S. Data 5 -
5T.M.D.S. Data 4+ 13 T.M.D.S. Data 3+ 21 T.M.D.S. Data 5+
6 DDC Clock (SCL) 14 +5V Power 22 T.M.D.S. Clock shiel d
7 DDC Data (SDA) 15 Ground (return for +5V,
Hsync and Vsync)
23 T.M.D.S. Clock+
8 NC* 16 Hot Plug Detect 24 T.M.D.S. Clock-
(*NC: No Connection)
SIGNAL2 : Gilt nur für SingleLink
Pin No. Signal Pin No. Signal Pin No. Signal
1T.M.D.S. Data 2- 9T.M.D.S. Data1- 17 T.M.D.S. Data0-
2T.M.D.S. Data 2+ 10 T.M.D.S. Data1+ 18 T.M.D.S. Data0+
3T.M.D.S. Data2/4 Shield 11 T.M.D.S. Data1/3 Shield 19 T.M.D.S. Data0/5 Shield
4 NC* 12 NC* 20 NC*
5 NC* 13 NC* 21 NC*
6 DDC Clock (SCL) 14 +5V Power 22 T.M.D.S. Clock shiel d
7 DDC Data (SDA) 15 Ground (return for +5V,
Hsync and Vsync)
23 T.M.D.S. Clock+
8 NC* 16 Hot Plug Detect 24 T.M.D.S. Clock-
(*NC: No Connection)
•USB Port
Upstream Downstream
Serie B Serie A
No. Signal Anmerkun gen
1 VCC Cable power
2 - Data Serial dat a
3 + Data Ser ial data
4 Ground Cable Ground