Opti RGB |
|
| DMX Values and Functions | |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Channel |
| Value |
|
| Function | |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
| 0 | - 255 |
|
|
| RED | |||||||||
|
|
|
| 0% |
|
|
|
|
| 100% | ||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
| 0 | - 255 |
|
| GREEN | ||||||||||
|
|
|
| 0% |
|
|
|
|
| 100% | ||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
| 0 | - 255 |
|
|
| BLUE | |||||||||
|
|
|
| 0% |
|
|
|
|
| 100% | ||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4 |
| 16 | - 255 | COLOR MACRO | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
5 |
| 0 | - 15 |
|
| NOTHING | ||||||||||
|
| 16 | - 255 | STROBING/SPEED CONTROL | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
6 |
| 0 | - 31 |
|
| NOTHING | ||||||||||
|
|
|
| DIMMING CONTROL | ||||||||||||
|
| 32 | - 63 |
| DIM |
|
|
| BRIGHT | |||||||
|
|
|
| |||||||||||||
|
| 64 | - 95 |
| BRIGHT |
|
|
| DIM | |||||||
|
|
|
| |||||||||||||
|
| 96 | - 127 | DIM |
| BRIGHT |
| DIM | ||||||||
|
|
|
| |||||||||||||
|
| 128 | - 159 |
| COLOR MIXING | |||||||||||
|
| 160 | - 191 | 3 COLOR CHANGE | ||||||||||||
|
| 192 | - 223 | 7 COLOR CHANGE | ||||||||||||
|
| 224 | - 255 |
| SOUND ACTIVE | |||||||||||
|
|
|
|
|
|
|
|
| ||||||||
7 |
| 0 | - 255 |
|
| DIMMING | ||||||||||
|
|
|
| 0% |
|
|
|
| 100% | |||||||
|
|
|
|
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Channel 1, 2, and 3 will not work, when Channel 4 is being used. When units are daisy chained together in DMX Mode, channels 1, 2, and 3 must be “OFF” for units to sync together when using Channel 4.
When the value of Channel 6 is between 32 and 127, you must be using Channels 1, 2, 3, or all three combined.
When using Channel 6, Channel 5 will control the speed of the color changing.
Opti RGB | Cleaning |
Due to fog residue, smoke, and dust cleaning the internal and exter- nal optical lenses must be carried out periodically to optimize light output.
1.Use normal glass cleaner and a soft cloth to wipe down the outside casing.
2.Clean the external optics with glass cleaner and a soft cloth every 20 days.
3.Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew).
Opti RGB | Trouble Shooting |
Listed below are a few common problems the user may encounter, with solutions.
Unit not responding to DMX:
1.Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right connectors; it does matter which way the inputs and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
Elation Professional - www.elationlighting.com - Opti RGB Instruction Manual Page 9 | Elation Professional - www.elationlighting.com - Opti RGB Instruction Manual Page 10 |