14

If, after carrying out the necessary checks there is still a fault withyour appliance please contact your local AEG Service Force Centre.In guarantee customers should ensure that the suggestedchecks have been made as the engineer will make a charge if thefault is not a mechanical or electrical breakdown.Please note that proof of purchase is required for any in-guaranteeservice calls.
Heavy build up of frost, pos-
sibly also on the door seal.
Door seal is not air tight
(possibly after changing
over the hinges).
Carefully warm the leaking
sections of the door seal
with a hair dryer (not hotter
than approx. 50 ¡C). At the
same time shape the war-
med door seal by hand until
it sits correctly.
The food is too warm.
The appliance is near a heat
source.
Temperature is not properly
adjusted.
Please look in the "Initial
Start Up" section.
Turn the temperature control
knob to a colder setting.
Door was open for an exten-
ded period.
Please look in the "Installa-
tion location" section.
Alarge quantity of warm food
was placed in the appliance
within the last 24 hours.
Open the door only as long
as necessary.
Symptom Possible Cause Remedy
Appliance does not work.
Appliance is not switched on Switch on the appliance.
Mains plug is not plugged in
or is loose.
Insert mains plug.
Fuse has blown or is defec-
tive.
Check fuse, replace if
necessary.
Socket is defective. Mains malfunctions are to be
corrected by an electrician.
Appliance cools too much. Temperature is set too cold. Turn the temperature control
knob to a warmer setting.
The compressor starts after
a period of time.
This is normal, no error has
occurred.
The compressor does not
start immediately after chan-
ging the temperature set-
ting.