Installation
If your refrigerator is installed under |
|
|
a continuous worktop, an air outlet | 105 | |
opening of at least 200 cm2 and a |
|
|
ventilation grille (A/B) matching the |
|
|
worktop design should be installed at |
|
|
the rear of the worktop. |
|
|
The cut surfaces of the worktop (C) |
|
|
should be varnished to avoid swelling |
|
|
due to penetration of moisture. |
|
|
The appliance wall distance must be |
|
|
at least 30 mm and should be | AEG36 |
|
|
|
checked before the ventilation grille is inserted.
Special accessories:
A Ventilation grille, brown
B Ventilation grille, white
A/B
200 cm2
C
570
550
Reversing the door
The side at which the door opens can be changed from the right side (as supplied) to the left side, if the installation site requires.
Warning! When changing the side at which the door opens, the appli- ance must not be connected to the mains. Remove plug from the mains beforehand.
☞1. Tilt the appliance slightly towards the rear and prop it securely.
2. Unscrew the door hinge screws (K) and remove the hinge pin bracket (1).
1
3. Open the door a little way and take it out downwards.
4.Unscrew the upper pin (A) and screw it into place on the opposite side.
5.Fit the door into the upper pin (A) and close it.
6.Screw the hinge pin bracket (1) securely into place on the opposite side using the screws (K).
K
A | 12 |
|