Fault Finding

Preliminary Electrical Systems Check

START

Isolate appliance and carry out:

A:Earth Continuity check.

 

 

 

 

 

 

 

 

NO

YES

Carry out:

 

 

 

 

 

C: Polarity check.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brown Blue Green Yellow

Blue

Brown Green

Yellow

Carry out:

D:Resistance to Earth check.

Has inlet fuse blown?

NO

Inlet wiring faulty. Rectify any fault.

 

 

 

 

 

 

 

 

Electricity supply

 

 

 

should now be

YES

satisfactory.

 

 

 

 

 

PLUG(withcoverremoved)

SOCKET

 

EarthWire

 

 

(faceview)

 

 

 

 

Green/Yellow

(

)

E (

)

 

 

 

 

NeutralWire

 

FUSE

 

 

Blue

 

 

 

 

 

 

 

 

 

N

 

L

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fusesasnecessary.

55