Electrolux 20604 G - 21604 Commissioning, Pressure Testing, Remove the control knob

Models: 20604 G - 21604 G-11602, G-21602

1 26
Download 26 pages 10.51 Kb
Page 24
Image 24

Commissioning

When the hob has been fully installed it will be necessary to check the minimum flame setting. To do this, follow the procedure below.

Φ1) Turn the gas tap to the MAX position and ignite.

2)Set the gas tap to the MIN flame position then turn the control knob from MIN to MAX several times. If the flame is unstable or is extinguished follow the procedure below.

Procedure:

Φ1) ReMIN-ignite.the burner and set to

2)Remove the control knob.

3)You can find two different adjustment screw locations according to the gas tap (see diagram). The "b" type has the adjustment screw located down the centre of th egas tap control shaft. The "c" type has the by pass screw located to the side of the gas tap itself.

FO 1032

a)Minimum adjustment screw

b)Tap

To adjust, use a thin bladed

screwdriver and turn the adjustment screw until the flame is steady and does not extinguish, when the knob is turned from MIN to MAX. Repeat this procedure for all burners.

Pressure Testing

Φ1) Remove left hand pan support and front left burner cap and crown.

2)Fit manometer tube over the injector.

3)Turn on the burner gas supply and ignite another burner supply.

The pressure reading should be nominally 20mbar and must be between 17 mbar and 25mbar.

4)Turn off the burner supplies.

58