II
FINAL INSTALLATION CHECK
Once you have completed the installation of the dryer and it is in its final location, confirm proper operation with the following steps and tests.
O Is gas turned ON? (Gas Models only)
O Is dryer plugged in? Dryer should always be plugged into the proper outlet.
Gas dryer should use a
© Electric dryer should use
a
required for all mobile and manufactured home
installations, as well as all new construction after
January 1, 1996.
© A
is NOT permitted on new construction after
January 1, 1996.
O Is dryer vent ductwork connected?
OIs dryer level?
O Perform the following tests before using the dryer.
Testing Dryer Heating
GAS MODELS
O Close the dryer door.
O Press the Power button to turn the dryer on.
O Turn Cycle Selector Knob to Normal drying cycle.
O Press the Cycle Selector Knob to start the dryer.
When the dryer starts, the igniter should ignite the main burner.
O After 2 minutes, open the door and check for heat. no heat is felt, verify the gas valve is on and check other gas appliances for proper operation.
NOTE: If all air is not purged from the gas line, the gas igniter may turn off before the main burner ignites. If this happens, the igniter will reattempt gas ignition until all the air is purged from the gas line.
ELECTRIC MODELS
O Close the dryer door.
O Press the Power button to turn the dryer on.
O Turn Cycle Selector Knob to Normal drying cycle.
O Press the Cycle Selector Knob to start the dryer. The exhaust air should be warm after the dryer has been operating for 3 minutes.
O After 2 minutes open the door and check for heat. If no heat is felt, verify that BOTH breakers or fuses are not tripped. Check for proper power cord wiring and power supply.
Checking Venting
Vent ductwork should be checked for lint buildup and cleaned at least once per year. If any noticeable reduction in drying performance occurs, check ductwork for obstructions and blockages.
Checking Levelness
Once the dryer is in its final location, recheck the dryer to be sure it is level. Make sure it is level front to back
and side to side, and that all 4 leveling feet rest firmly on the floor.