Kenmore 796.6927#, 796.7927# KEY Dimensions Specifications, Location Requirements, Clearances

Models: 796.7927# 796.6927#

1 72
Download 72 pages 13.08 Kb
Page 8
Image 8

 

KEY DIMENSIONS

AND SPECIFICATIONS

Description

 

Dryer (Gas and Electric)

Electrical Requirements

Please refer to the rating label.

Gas

Requirements*

Natural:

6-8 inches WC

Gas

Requirements*

Propane:

10-13 inches WC

Dimensions

 

27" (W) X 28 154 6" (D) X 45" (H), 50 1/4" (D With door open)

 

 

 

68.60m (W) X 73.4 cm (D) X 114.10m (H), 127.5 cm (D With door open)

Net Weight

 

Electric : 147 lb. (66.7kg) / Gas : 150.5 lb. (68.3kg)

Drying Capacity

 

IEC 7.3 cu. ft.

*Gas

Models only.

 

 

LOCATION REQUIREMENTS

IMPORTANT:

Read all installation instructions completely before installing and operating your dryer!

It is important that you review this entire manual before installing and using your dryer. It contains detailed instructions concerning electrical connections, gas con- nections and exhaust requirements.

21 1/4''l

(54 ore)

CHOOSE THE PROPER LOCATION

Store and install the dryer where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.

Choose a location with a solid, level floor.

If the dryer is being installed in a garage, place the dryer at least 18 inches (45.7cm) above the floor.

Properly ground the dryer to conform with all governing codes and ordinances.

To reduce the risk of electric shock, do not install the dryer in damp or wet locations.

IMPORTANT: If you are installing your dryer in a manufactured or mobile home, please refer to the section Special Electrical Requirements for Mobile or Manufactured Homes on page 12,

CLEARANCES

Most installations require a minimum 5-1/2 in. (14 cm) clearance behind the dryer for

the exhaust ducting.

Allow minimum clearances of at least 1 in.

(2.5 cm) on the sides and back to minimize vibration and noise.

Allowing additional clearance for installation and servicing is recommended.

Be sure to allow for wall, door, or floor moldings that may increase the required clearances.

Allow at least 21 inches (53.3 cm) in front of the dryer to open the door.

....

:

(68.6 cm)

_11_1"

 

 

 

 

 

27"

(2.5 cm)

501/4"

(127.5 cm)

 

3"

 

/

(7.6 cm)

1

 

 

 

48 sq. in. /

48 in.2 z

 

(310 cm2)

 

(310 cm)

 

 

 

0

 

0

34 sq. in.

34 in.2

 

(155 cm2)\

(155 cm) \

 

\

--...,

3" _L

\

(7.6 cm)

Closet Door Clearance Requirements

Additional Instructions for closet installations:

The closet door must allow for sufficient airflow. Refer to the diagram to the left for minimum vent opening or door clearance requirements. A Iouvered door is also acceptable.