CONNECTING ELECTRIC DRYERS (cont.)

CONNECTING ELECTRIC DRYERS

,A WARNING

. Connect the power cord to the terminal block. Each colored wire should be connected to same color screw. Wire color indicated on manual is con- nected to the same color screw in block. Failure to follow these instructions may result in a short or overload.

. Grounding through the neutral conductor is pro- hibited for: (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Four-Wire Power Cord

and manufactured home installations, as

• A 4-wire connection is required for all mobile well as all new construction after January 1,

1996.

• A UL-listed strain relief is required.

Use a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.

Three-Wire Power Cord

©

° A 3-wire connection is NOT permitted on

new construction after January 1, 1996.

A UL-listed strain relief is required.

Use a 30-amp, 240-volt, 3-wire, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.

 

Terminal

Block

Block

UL-Listed

Strain Relief

PowerCor

@Remove the terminal block access cover on the upper back of the dryer.

O Install a UL-listed strain relief into the power cord through-hole.

tD Thread a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimumcopper conductor through the strain relief.

Hot

_ Neutral

(Black) '

Ground Wire :

- UL-Listed 3-Wire

Power Cord

@Remove the terminal block access cover on the upper back of the dryer.

O Install a UL-listed strain relief into the power cord through-hole.

tD Thread a 30-amp, 240-volt, 3-wire, UL-listed power cord with #10 AWG-minimumcopper conductor through the strain relief.

Neutral

(Black)

Hot

Ground Screw

/I/Ill

White wire from."

dryer harness

O Transfer the dryer's white ground wire from behind the green ground screw to the center screw of the termi- nal block.

O Attach the two hot leads of the power cord to the outer

terminal block screws.

 

I_)Attach the white neutral wire to the center screw of

 

the terminal block.

 

O Attach the power cord ground wire to the green

 

ground screw.

 

O TIGHTEN ALL SCREWS SECURELY.

 

O Reinstall the terminal block access cover.

13

@Attach the two hot leads of the power cord to the outer terminal block screws.

O Attach the neutral (center) wire to the center terminal block screw.

O Connect the external ground (if required by local codes) to the green ground screw.

O TIGHTEN ALL SCREWS SECURELY.

O Reinstall the terminal block access cover.

Page 13
Image 13
Kenmore 796.7927#, 796.6927# manual Connecting Electric Dryers, Four-Wire Power Cord, Three-Wire Power Cord