8Operation
Description of Features
vacation mode | Conserves energy by disabling interior |
| lights and keypad inputs. |
mute sounds | Tones emitted by each keypress can be |
| turned off based on user preference. The |
| sounds are muted when the red indicator |
| is lit. The mute sounds key also is used |
| to acknowledge alarm conditions, denoted |
| by a flashing red indicator. Press and |
| hold the mute sounds key for three (3) |
| seconds then release to enable control |
| lock, which prevents undesired changes |
| to the unit settings. Temperature display |
| will show “LOC”. |
temperature | Simultaneously press and hold the (+) and |
| |
| ing the key causes the temperature display |
| to toggle from Fahrenheit to Celsius and |
| back again. |
on off | Press and hold for three (3) seconds then |
mode | release the key. This allows the user to |
| turn off the cooling system. The tempera- |
| ture display will display “OFF”. THIS DOES |
| NOT REMOVE POWER FROM THE UNIT. |
Alarms |
|
door ajar | If the door has been left open for five (5) |
| minutes, an audible alarm will sound and |
| the door ajar indicator will illuminate on |
| the right side of the display. The mute |
| sounds indicator will blink. Pressing |
| and releasing the mute sounds key will |
| acknowledge the alarm and disable the |
| audible portion. The door ajar indica- |
| tor will continue to blink until the door is |
| closed. |
high temp | In the event of a high temperature condi- |
| tion, an audible alarm will sound, the |
| temperature display will blink and display |
| “HI”, and the high temp indicator on the |
| right side of the display will blink. The |
| mute sounds indicator will blink. Press- |
| ing and releasing the mute sounds key |
| will acknowledge the alarm and disable |
| the audible portion. All other modes are |
| turned off until the alarm is acknowledged. |
| The high temperature indicator and |
“HI” will stay illuminated until a normal safe range operating temperature has been reached, at which time the temperature display will show the actual temperature.
power fail In the event of a power failure or initial
Notifications
air filter | After six months of use the display will |
| show AF. This is a reminder that it is |
| time to change the PureAdvantageTM |
| air filter. The product will continue to |
| function normally. Pressing any key will |
| reset the reminder for 10 minutes. Once |
| the PureAdvantageTM air filter is replaced, |
| pressing the “On/Off” and “– “ keys for |
| three seconds will reset the reminder for |
| another six months. |
Sabbath Mode
Sabbath mode disables portions of the unit and its controls in accordance with
the weekly Sabbath and religious holidays observed within the Orthodox Jewish community.
Sabbath mode is enabled and disabled by pressing and holding the vacation mode key for five (5) seconds and then releasing the key. Temperature display shows “Sb” while in Sabbath mode.