SERVICE DATA SHEET - 242173700

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°

CONTROL SETTING (2500++ V4 CONTROLS)

SERVICE DATA SHEET - 242173700

FREEZER ICE MAKER - AUTOMATIC DEFROST

BOTTOM FREEZER - R134a

ICE MAKER INFORMATION

Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counter- clockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle.

Variable Speed Compressor

65°F (18°C) Ambient

90°F (32°C) Ambient

 

 

 

Operating Time

32 to 40%

100%

 

 

 

Freezer Temperature

-6° to 6°F

-6° to 6°F

-21° to -14°C

-21° to -14°C

 

 

 

 

Refrigerator Temperature

33° to 46°F

33° to 46°F

0.5° to 8°C

0.5° to 8°C

 

 

 

 

Low Side Pressure

5 to 12 psig

N/A

(cut-in)

34 to 83 kPa

 

 

 

 

Low Side Pressure

-2 to 2 psig

-2 to 2 psig

(cut-out)

-14 to 14 kPa

-14 to 14 kPa

 

 

 

High Side Pressure

85 to 95 psig

120 to 135 psig

586 to 655 kPa

827 to 931 kPa

 

 

 

 

Wattage

40 to 55

60 to 70

FREEZER ICE MAKER - AUTOMATIC DEFROST IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.

IMPORTANT

If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.

Water Fill Volume: The water fill adjust- ment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked.

Water Fill

Adjustment

Motor

Gear

TUR

N

Mounting

Plate

Screw

Mounting

Plate

Screws

Timing

Gear

Amps (running)

 

0.5 to 1.1

 

0.7 to 0.9

 

 

 

 

 

 

 

 

Base Voltage

 

115 vac (127 vac max)

 

 

 

 

 

 

 

 

 

 

 

 

DEFROST SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

Cabinet Size

 

Thermostat

 

 

Heater

 

 

 

 

 

 

 

 

Cut-in

Cut-out

 

Watts

 

Ohms

 

 

 

 

 

 

 

 

 

 

 

 

23’ SD, 28’ SD, 23’ CD

 

25°F

47°F

 

500

 

26

 

(-4°C)

(8°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

CONDENSER FAN MOTOR

ICE MAKER INFORMATION CAUTION

All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.

NOTE

This product comes equipped with an Adaptive Defrost Control (ADC). To activate

LINE

/ ORG

POWER

ICE MAKER

NEUTRAL

BLUE/

Watts

RPM

 

Amps

 

 

 

 

3.1

1100 CW

 

0.03 Running

(Energy Star, some models)

Opposite Shaft

 

 

 

 

 

 

 

FREEZER ICE MAKER SPECIFICATIONS

 

 

 

 

Electrical

115 vac (127 vac max)

 

 

 

Thermostat

Opens at 48°F (9°C), Closes at 15°F (-9°C)

 

 

 

Heater Voltage

85 vac

 

 

 

FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS

 

 

 

Wire Number

Wire Color

Connects to:

 

 

 

1

Green / Yellow

Ground

 

 

 

2

Yellow / Blue

Water Valve

manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A “d” in the freezer temperature window and “F” in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A “d” and “F” will be displayed until the defrost cycle is complete.

 IMPORTANT SAFETY NOTE IMPORTANT

BLK

P-3

ICE MAKER

GRN / YEL

P-1

BLK

THERMAL

CUT-OUT

BLK

GRN / YEL

BRN

MOTOR

 

 

RED

 

 

 

 

 

 

 

 

 

HOLD

 

 

 

 

 

 

SWITCH NO

 

YEL

 

 

 

RED

NC

THERMOSTAT

 

YEL

 

C

 

 

 

 

 

 

NO

RED

 

 

 

 

 

BLK

 

 

BLU

 

 

 

 

 

NC

 

 

 

 

 

C

 

 

 

 

 

 

 

MOLD HEATER

 

 

 

SHUTOFF

 

165 WATTS

 

 

NO

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

C

NC

 

LT. BLUE

 

 

 

 

 

 

 

YEL

ICE MAKER

PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.P-2

BLUE

WATER VALVE

LT.

 

Manual backgroundP-4

3

Black / Orange

Line

 

 

 

4

Light Blue

Neutral

PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

MOLD

MOUNTING

 

WATER FILL

 

PLATE

 

SWITCH

 

ICE MAKER

 

 

 

 

 

 

 

Page 1
Image 1
Electrolux 242173700 specifications Service Data Sheet, Important Safety Note, Ice Maker Information