NOTE: A 60" (152,4 cm) long cable is supplied with the Warm & Serve Drawer.
Stand Alone Installation

WARM & SERVE DRAWER INSTALLATION INSTRUCTIONS

Canada

INSTALLATION AND SERVICE MUST BE PERFORMED

BY A QUALIFIED INSTALLER.

IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

WARNING FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

United States

GENERAL INFORMATION: The Warm & Serve Drawer can be used as a stand alone appliance or combine with a built-in oven mounted above.

IMPORTANT: The warmer drawer must be installed on a leveled surface from left to right, rear to front and the surface must be capable of supporting 100 lbs (45,4 Kg).

Warm & Serve Drawer Dimensions

IMPORTANT: The Warm & Serve Drawer runs off a single phase three-wire 120 volt, 60 hertz, AC only electrical supply with ground.

C

B

F

D

E

Minimum distance to floor 4½" (11,4 cm)

A.HEIGHT 10 ¾" (27,3 cm)

D.cutout height

Min.

9 7/8" (25,1 cm)

Max.

10 ¼" (26 cm)

 

 

60" (152,4 cm) Cord

Warm and Serve

Drawer

A

Warm and Serve

Cutout

FLOOR

B. WIDTH

 

C. Depth

29" (73,7 cm)

 

23 3/8" (59,4 cm)

E. cutout

 

F. cutout

 

width

 

depth

28 ½" (72,4 cm)

 

23 5/8" (60 cm)

28 ¾" (73 cm)

 

24" (61 cm)

 

 

 

Combination Warm & Serve Drawer/

Built-in Oven Installation

Caution: Two 3" (7,6 cm) wide X 3/4" (1,9 cm) thick planks have to be install and they should be able to support 200 pounds. (90,7 Kg)

 

of oven cutout

29½"

Bottom

 

(74,9cm)

 

H* = 11 5/8" (29,5cm) Min. is a Critical dimension and has to be respected.

J** = 3" (7,6cm) Max. Electrical Junction Box for wall oven must be lower than warmer drawer cutout.

 

A. HEIGHT

B. WIDTH

C. Depth

10 ¾" (27,3 cm)

29" (73,7 cm)

23 3/8" (59,4 cm)

 

 

 

 

 

 

 

D. cutout

E. cutout

F. cutout

G. HEIGHt

 

 

height

width

depth

 

Min.

 

9 7/8" (25,1 cm)

28 ½" (72,4 cm)

24" (61 cm)

1 ¾" (4,4 cm)

Max.

 

10 ¼" (26 cm)

28 ¾" (73 cm)

 

Depends on critical

 

 

 

 

 

dimension H

P/N 318201808 (0901) Rev. C

 

English – pages

1-4

 

Español – páginas

5-8

Printed in the USA

Français – pages 9-12

1

Page 1
Image 1
Electrolux 318201808 installation instructions Warm & Serve Drawer Dimensions