CONSTRUCTION
•Internal and external finishing in 304 AISI stainless steel and backpanel in galvanized steel.
•High density polyurethane insulation, 60 mm tickness, HCFC free.
•Environmentally friendly: R134a as refrigerant fluid.
•Developed and produced in ISO 9001 and ISO 14001 certified factory.
•Inner cell with fully rounded corners.
•Door equipped with removable magnetic gasket with hygienic design.
•Motors and fan waterproof protected IP20.
•Evaporator with antirust protection.
Electrolux Blast Chillers
Blast Chillers - 10/15 kg
•Ventilator (fan) swinging hinged panel for access to the evaporator for cleaning.
•Automatic heated door frame.
•Thermostatic expansion valve to optimize the cooling unit efficiency.
•Adjustable feet 150 mm high (except for code 726658).
•Stand alone printer as accessory.
•PC connection on request, gate RS 485.
INSTALLATION
•No water connections required.
•Waste water can be plumbed into drain, but can also be collected in an optional waste container.
*NF HYGIENE ALIMENTAIRE certifying authority : AFAQ AFNOR CERTIFICATION. Adress:11, Avenue Francis de Pressense - 93571
|
|
|
| HDAA010 | |
| RBC051 | RBC061 | RBC061R | ||
| 726658 | 726620 | 726621 |
| |
TECHNICAL DATA |
|
|
|
| |
|
|
|
| ||
Type | A - 10 KG CHILLER | B - 15 KG CHILLER | B - 15 KG CHILLER |
| |
Productivity per cycle - kg. |
|
|
|
| |
NF Regulations - chilling / freezing | 7.2 | 10.8 | 10.8 |
| |
UK Guide lines - chilling / freezing | 10 | 15.2 | 15.2 |
| |
Gross capacity (D.I.N. 8952) - l. | 72 | 115 | 115 |
| |
Cooling unit | Remote |
| |||
External dimensions - mm |
|
|
|
| |
width | 762 | 760 | 760 | 06 | |
depth/with open doors | 700, 1407 | 760, 1500 | 770, 1450 | 10- | |
height | 850 | 970 | 975 | - | |
2009 | |||||
N° and type of door | 1 | 1 | 1 | ||
| |||||
Door hinges | Right Side | Right Side | Right Side |
| |
Trays type | GN 1/1; 600x400 | GN 1/1; 600x400 | GN 1/1; 600x400 |
| |
Max load capacity - trays h 65 mm - n° | 3 | 3 | 3 |
| |
Compressor power - HP | 1/4 | 3/8 |
|
| |
N° defrost in 24 hrs. |
| 6 | 6 |
| |
Refrigerant type | R134a | R134a | R134a |
| |
Refrigerant quantity - g. | 1100 | 1100 |
|
| |
Refrigeration power - W | 980 | 707 | 1350 |
| |
Refrigerant power |
|
|
|
| |
at evaporation temperature - °C | 7.3 | 7.2 |
| ||
Power - kW |
|
|
|
| |
0.51 | 0.715 | 0.12 |
| ||
Net weight - kg. | 88 | 95 | 85 |
| |
INCLUDED ACCESSORIES |
|
|
|
| |
|
|
|
|
| |
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER |
| 1 | 1 |
| |
ACCESSORIES |
|
|
|
| |
|
|
|
|
| |
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER | 880089 | 880089 | 880089 |
| |
2 SINGLE SENSOR PROBES CHILLER+C/FREEZER | 880096 | 880096 | 880096 | notice | |
880088 | 880088 | 880088 | |||
| |||||
4 FEET FOR UNDERCOUNTER BLAST CHILLER | 881493 |
|
| without | |
COOK&CHILL |
| 881528 | 881528 | ||
4 WHEELS FOR BLAST CHILLERS |
| 881097 |
|
| |
|
|
|
| changeto | |
KIT HACCP EKIS | 922166 | 922166 | 922166 | ||
KIT 3 SINGLE SENSOR PROBES FOR BC/BCF |
| 880269 | 880269 |
| |
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW | 880183 | 880183 | 880183 |
| |
|
|
|
|
| |
PAIR OF 1/1 GN AISI 304 S/S GRIDS | 921101 | 921101 | 921101 | Subject | |
PLASTIC COATED |
| 880864 | 880864 | ||
|
| ||||
PRINTER FOR HACCP BASIC VERSION | 881532 | 881532 | 881532 |
| |
RILSAN COATED GRID |
| 881061 | 881061 |
|
Internet: http://www.electrolux.com/foodservice