Charcoal filter
•The charcoal filter is already supplied and mounted in place.
•The charcoal filter should only be used if you want to use the hood in the recirculation function.
•Only applicable for recirculation. The charcoal filters absorb smells and odours.
•The charcoal filter cannot be washed nor regenerated.
The charcoal filter should be replaced every 6
months under normal use.
Replacement filters are available from your local Service Force Centre.
Fitting:
•Unplug the unit or disconnect it from the power supply
•Remove the metal grease filter.
•Fit the charcoal filter and fix it to the body of the hood with two supplied screws.
•Refit the metal grease filters.
•To remove proceed in the reverse order.
•Always specify the hood model code number and serial number when ordering replacement filters. This information is shown on the registration plate located on the inside of the unit.
•The charcoal filter can be ordered from your local ELECTROLUX Service Force Centre.
Charcoal |
|
filter | Screw |
Screw |
|
Grease |
|
filters |
|
Fig. 5 - Fitting the Charcoal Filter
Changing the light bulb
• Disconnect the cooker hood from the main |
| |
supply. |
| |
• Remove the lamp cover, use a screw driver as a |
| |
lever. |
| |
• Replace the old bulb with a new one of the |
| |
same type. |
| |
• Refit the lamp cover. |
| |
• If the light does not come on, make sure the |
| |
bulb has been inserted correctly before |
| |
contacting your local Service Force Centre. | Fig. 6 - Changing the light bulb |