74
Installation
Preparing the wall unit - Extractor version
The hood is supplied as an
extractor unit.
Before installing the hood, drill a
hole in the roof of the wall unit
(see Fig. 5). This hole is to allow
passage of the outlet pipe and the
power cable, and to facilitate
servicing.
The wall unit must have a
minimum body depth (without
door) of 300 mm with recessed
light screen and min. 370 mm with
flush-mounted light screen. The unobstructed internal height must be
at least 370 mm.
Preparing the wall unit - Filter version (DF 6160)
Before installation of the hood in the wall unit, a 115x115 mm hole for
the deflector should be cut in the ceiling of the wall unit. Fig. 6-7.
Depending on the wall unit height, you need for return air operation a
pipe union or additionally a non-flammable length of pipe (Ø 100/115/
120 mm) as far as the ceiling of the wall unit.
190
238
172
Fig. 5
Fig. 6 Fig. 7