electrolux 9

Installation

Read the "Safety Information" carefully for your safety and correct operation of the appliance before installing the appliance.

Positioning

Install this appliance at a location where the ambient temperature corresponds to the cli- mate class indicated on the rating plate of the appliance:

Climate

 

Ambient temperature

class

 

 

SN

 

+10°C to + 32°C

N

 

+16°C to + 32°C

ST

 

+16°C to + 38°C

T

 

+16°C to + 43°C

 

 

 

Electrical connection

Before plugging in, ensure that the voltage and frequency shown on the rating plate cor- respond to your domestic power supply. The appliance must be earthed. The power supply cable plug is provided with a contact for this purpose. If the domestic power sup- ply socket is not earthed, connect the appli- ance to a separate earth in compliance with current regulations, consulting a qualified electrician.

The manufacturer declines all responsibility if the above safety precautions are not ob- served.

This appliance complies with the E.E.C. Di- rectives.

Door reversibility

The door of the appliance opens to the right. If you want to open the door to the left, follow these steps before you install the appliance:

1.Loosen and remove the upper pin.

2.Remove the door.

3.Remove the spacer.

4.With a key, loosen the lower pin.

On the opposite side:

1.Tighten the lower pin.

2.Install the spacer.

3.Install the door.

4.Tighten the upper pin.

Ventilation requirements

The airflow behind the appliance must be sufficient.