Electrical connection (NOT FOR UK)

Safety warnings for the electrician

Before connecting the appliance to the power supply, check that the
voltage indicated on the rating plate corresponds to the mains power
supply available. Appliances fitted with a plug can be connected to any
standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must only
be installed by an electrician authorised by the local electricity board.
When installing, an omnipolar disconnector with a distance of at least 3
mm between contacts must be provided.
The manufacturer declines all responsibility for malfunctions resulting from
failure to comply with the above instructions.
Electrical connection
220-230 V by means of fixed power cable with plug.
(Fixed connection of the appliance must only be carried out by an au-
thorised electrician.).
Electrical connection (ONLY FOR UK)

Safety warnings for the electrician

The electric outlet should be placed on the wall inside the chimney. The
hood has a power cable, 150 cm, WITHOUT an earth connection and
the rated voltage is 220 - 240 V (CHDE 3160).
Connect the hood to the mains supply via a double pole switch
which has 3 mm minimum separation between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured blue must be connected to the terminal
which is marked with the letter N or coloured black, -
- the wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.