ADVICE FOR SAFETY
Gas connections
•Before installation ensure that the local distribution conditions (gas type and pressure) and the
•This appliance must be installed only in a room with good ventilation.
•This appliance must not connected to a chimney. It has to be installed and connected in accordance with the rules in force. Special attention should be paid to the applicable disposal concerning ventilation.
•The adjacent furniture panels have to be heat proof or protected by such material.
•The adjusting conditions of this appliance are mentioned on the rating plate.
Connection to gas supply.
Check that the gas flow and the diameter of the supply pipe is sufficient to supply all the appliances of the installation.
•Check that all connections are tight.
•Install an accessible and visible gas tap to isolate the appliance.
The manufacturer declines any responsibility for possible damages resulting from an installation which doesn't comply with current legislation.
-Installation of flues and ventilation for gas appliances of rated input not exceeding 60 kW (1st, 2nd and 3rd family gases) – Part 2 Specification for installation of ventilation for gas appliances – BS 5440;
-Gas burning appliances – Part 3 Domestic cooking appliances burning gas – BS 5386;
-Specification for installation of low pressure gas pipe work of up to 20mm (R1) in domestic premises (2nd family gas) – BS 6891;
-Pipe threads for tubes and fittings where
-Flexible hoses, end fittings and sockets for gas burning appliances – BS 669;
-Installation of domestic gas cooking appliances (1st, 2nd and 3rd family gases) – BS 6172: 1990;
Electrical connections
This cooker is designed to be connected to a
Before switching on, make sure the electricity supply voltage is the same as that indicated on the rating plate.
Any electrical work required to install this cooker should be carried out by a qualified electrician or competent person, in accordance with the current regulations.
This cooker must be earthed.
Check on the rating plate the value for the total connection power for establishing the fuse power.
Fuse capacity: max 5 A
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
Ensure that the supply cable does not come into contact with any part of the hatched area shown in the diagram.
connection of flexible hose
power
cord
Before connecting check that:
•The plug used for connection is easily accessible when the appliance is installed.
18