Electrolux DSO51GA manual Replace the nozzles of the hob burners, Hob burners

Models: DSO51GA

1 27
Download 27 pages 45.38 Kb
Page 23
Image 23
Replace the nozzles of the hob burners

Replace the nozzles of the hob burners

 Hob burnersBefore any modifications or conversion to a kind of different gas, you must DISCONNECT the cooker from the electricity supply and ensure that all control knobs are in the OFF position, and the appliance has cooled completely.

Adjustment of minimum level for the hob Hob burners

Remove the pan supports;

Remove the caps and the burner crowns;

Using a No 7 socket spanner unscrew the nozzles and replace them with those required

for the type of gas in use (see table no. 1). Reassemble the parts following the same procedure in reverse.

These burners do not need any primary air regulation.

Adjustment of minimum level for the hob

 

 

 

burners

 

 

 

The burner is correctly adjusted when the flame

 

 

 

is stable silent and goes out without any noise.

 

 

 

When changing the type of gas check that the

 

 

 

minimum level is correct. The air admission is

 

 

 

correct when the flame is about 4 mm in length.

 

correct

excess of

The top burners do not need adjustment of

no air

adjustment

air

primary air.

 

 

 

Check that, turning the knob quickly from the

 

 

 

maximum position to the minimum one, the flame

 

 

 

does not go out.

 

 

 

Hob burners

 

 

 

To adjust the minimum level:

Light the burner

Turn the knob to the position of the minimum flame;

Remove the knob;

Unscrew or screw the by-pass screw (on the right above of tap shaft) until a regular small flame is reached.

For LPG screw completely the by-pass

screw.

Reassemble the parts following the same procedure in reverse.

Check that, when turning the knob quickly from the maximum position to the minimum one, the flame does not go out.

23

Page 23
Image 23
Electrolux DSO51GA manual Replace the nozzles of the hob burners, Hob burners, Adjustment of minimum level for the hob