Over-the-Range Microwave
E30MH65GPS professional series
Locate 120V/60Hz grounded outlet inside upper cabinet |
|
Microwave MUST | Bottom edge of |
be mounted to | |
BOTH a top cabinet | cabinet MUST be |
AND a wall* | 33" min. from |
| cooking surface |
69" min. from floor to top of microwave
16 1/2" | Rear Wall | 33" | 12" |
min. |
| min. | |
| min. | ||
|
|
| |
| 30" min. |
|
|
| 5" min. |
| Backsplash |
|
|
|
30" min. 33" max.
*Can NOT be installed in island or peninsula cabinet arrangements
Cabinet MUST be capable of supporting a total load of 110 lbs.
16 3/8"
16 7/8"
1/2" lower extrusion
Power cord location
Blower plate allows for vertical(right top rear) or horizontal ducting
14 3/8" |
|
| 29 7/8" | |
|
| |||
| ||||
|
|
|
| |
16 1/8" |
|
|
| Allow at least 25 1/2" clearance |
| ||||
|
|
|
| for door depth when open |
|
|
|
|
30" Over-the-Range Microwave Specifications
•Product Weight – 75 Lbs.
•Voltage Rating – 120V/60Hz/20 Amp
•Connected Load (kW Rating) @120 Volts = 1.6kW
(For use on adequately wired 120V, dedicated circuit having
•Amps @ 120 Volts =14.5 Amps
•Always consult local and/or national electric codes.
•Grounded outlet should be located in cabinet above, with hole in base to route power cord. Carefully follow top template instructions for power cord clearance when installing beneath smooth, flat cabinets.
•Microwave’s ventilation system is convertible, designed for two types of exhaust – outside, using either vertical or horizontal ducting; or recirculating, requiring no ducting.
•For safe and proper installation, microwave MUST be mounted to
BOTH a top cabinet AND a wall, and connected to at least one wall stud. Can NOT be installed in island or peninsula cabinet arrangements.
•Cabinet bottom MUST be level to insure proper installation.
•Cabinet MUST be capable of supporting a total load of 110 lbs.
•Filler blocks recommended for installation when cabinet front hangs below recessed bottom shelf.
•Minimum distance of 33" required from cooking surface to bottom edge of top cabinet.
•Minimum distance of 69" required from floor to top of microwave.
•Opening between cabinets MUST be 30" wide and free of obstructions.
•Can only be installed over ranges or cooktops with 33" maximum width.
•Allow
Ducted Option Specifications
•For outside ventilation only.
•Exhaust duct adapter supplied assembled for outside ventilation, designed to mate with standard
•For most efficient airflow exhaust, use a straight run or as few elbows as possible with maximum duct length of
•For horizontal installation, be sure to allow enough space between wall studs to accommodate exhaust.
•Refer to web for detailed duct preparation instructions.
Ductless (Recirculated) Option Specifications
•If ducting to outside is not an option, ventilation system can be converted to ductless to recirculate air inside.
•Refer to web for detailed convertible ventilation installation instructions.
Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxicon.com for detailed instructions.
USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • | High standards of quality at Electrolux Home Products, Inc. mean we are | |
constantly working to improve our products. We reserve the right to change | ||
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • | ||
specifications or discontinue models without notice. |
E30MH65GPS 03/08 | © 2008 Electrolux Home Products, Inc. | Printed in the U.S.A. |