Clearance Heights

The cooker hood is designed to be fitted over a cooking appliance at the clearance heights stated, providing the maximum output of the appliance beneath does not exceed the maximums quoted in the Technical Specifications.

If the output of the appliance below the cooker hood exceeds the maximum outputs quoted, please refer to the cooker manufacturer’s installation instructions.

A minimum clearance height of 650mm (25 ins) is required when installed above a built-in electric hob, or 700mm (25 ins) when installed above a built-in gas hob.

A minimum clearance height of 685mm (27 ins) is required when installing above a slot-in electric cooker, or 787mm (30 ins) when installed above a slot-in cooker.

When installed between adjoining wall cabinets, the wall cabinets must not overhang the hob and the distance between the underside of the cabinet and the worktop must be 450mmm (17 ins), a gap of 50mm (2 ins) must be maintained either side of the hob.

This cooker hood must not be installed above a cooking appliance with a high level grill.

Fitting the Wall Brackets

1.Draw a vertical line on the wall, from the centre of the cooking appliance up to the ceiling, using a spirit level and marker pen. This is to ensure the correct vertical alignment of the appliance.

2.Fixing the wall bracket No 1

Draw two horizontal lines through the vertical at 225 and 265mm as illustrated. Place the top edge of the bracket against the 265mm line, aligning the centre of the bracket with the vertical line. The line at should run through the centre of the keyholes. If, the alignment is correct mark

the centres for the key hole bracket fixing

Fig.3

screws (not supplied) as illustrated in Fig.

 

3.

 

Ensure that the distance between the lowest point of the hood and the cooking appliance beneath meet the clearance requirements quoted above.

Ensure the lower bracket 1 is fitted with the flat top pointing away from the wall.

12

Page 12
Image 12
Electrolux EFC 635, EFC 935 manual Clearance Heights, Fitting the Wall Brackets, Fixing the wall bracket No