Electrolux EFC 635, EFC 935 manual

Models: EFC 635 EFC 935

1 20
Download 20 pages 50.24 Kb
Page 14
Image 14
Fig.5

Fitting the Canopy Hood

1.Adjust the two screws V on the top of the canopy to about halfway as illustrated in Fig. 5.

2.Hook the canopy onto the wall bracket 1 and push down until the canopy adjusting screws V rest on the bracket, turn the screws to adjust the canopy vertically and level it horizontally as illustrated in Fig. 5.

4.Insert the screw V1 into the central hole to lock the canopy in to position as illustrated in Fig. 5.

Electrical connection and working test Before fitting the chimney to the canopy make the electrical connection as described in the section titled “ELECTRICAL CONNECTION”.

When the electrical connection has been made, test the three speed fan and worktop illumination.

Venting

The hood is more effective when used in the extraction mode (ducted to the outside). Venting kits may be purchased through your retailer or DIY store, and must be ducted to an outside vent of 125mm (5”).

The ducting used must be manufactured from fire retardent material conforming to the relevant British Standard or DIN 4102-B1.

When the cooker hood is ducted to the outside the charcoal filters must be removed.

Recirculation

The cooker hood is supplied specified for use in the recirculation mode, with the charcoal filters fitted.

In the recirculation mode contaminated air is passed through the charcoal filters to be purified and recirculated into the kitchen through the grille outlets on either side of the chimney (I).

To fit the recirculation spigot (R), place the spigot over the outlet on top of the canopy and push down on the spigot until it snaps into position as illustrated in Fig. 6.

Fig.5

Fig.6

14

Page 14
Image 14
Electrolux EFC 635, EFC 935 manual