Technical Specifications
Model |
| EFG 540 | EFG 535 |
Dimensions | Height (cm) | 13,9 | 13,9 |
| Width (cm) | 52,4 | 52,4 |
| Depth (cm) | 28,9 | 28,9 |
Lighting |
| 2 x 40 W | 2 x 40 W |
Grease filter |
| 2 | 1 |
Power absorption |
| 320 W | 200 W |
Electrical connection: |
Subject to change without notice.
Installation
Unpacking |
|
Check that the cooker hood has no damages. |
|
Transportation damages should immediately be |
|
reported to the company responsible for the |
|
transportation. |
|
Damages, faults and eventually missing details |
|
should immediately be reported to the retailer. |
|
Take care of the packing materials so that small |
|
children cannot play with them. |
|
Fitting | Fig. 9 |
| |
The hood is to be mounted on the wall. |
|
When installed, the hood must be not less than |
|
60cm. above electric burners or 70cm. above gas |
|
or |
|
The hood can be installed above these heights but |
|
for optimum performance it should be installed at |
|
the distance quoted for the appropriate heat source. |
|
Min | Min | |
70 cm | ||
60 cm | ||
|
Electrical connection for UK only
Safety warnings for the electrician
Connect the hood to the mains supply via a double pole switch which has 3 mm minimum separation between the contacts.
The switch must be accessible at all times. The following is valid in the United Kingdom only:
- the wire which is coloured blue must be
connected to the terminal which is marked with | Mounting accessories included | |
the letter N or coloured black, - | ||
| ||
- the wire which is coloured brown must be | 1 Coupling ring | |
connected to the terminal which is marked with | 108 metal screws 2,9 x 16 | |
the letter L or coloured red. |