13
Important safety requirements
This hob must be installed in accordance with the Gas
Safety (Installation and Use) Regulations (Current
Edition) and the IEE Wiring Regulations (Current
Edition).
Detailed recommendations are contained in the
following British Standards Codes Of Practice: B.S.
6172/ B.S. 5440, Par. 2 and B.S. 6891 Current
Editions.
The hob should not be installed in a bed sitting room
with a volume of less than 20 m3. If it is installed in a
room of volume less than 5 m3 an air vent of effective
area of 110 cm2 is required. If it is installed in a room
of volume between 5 m3 and 10 m3 an air vent of
effective area of 50 cm2 is required, while if the
volume exceeds 11 m3 no air is required.
However, if the room has a door which opens directly
to the outside no air vent is required even if the
volume is between 5 m3 and 11 m3.
If there are other fuel burning appliances in the same
room, B.S. 5440 Part 2 Current Edition, should be
consulted to determine the requisite air vent
requirements.

Location

The hob may be located in a kitchen, a kitchen/diner
or bed sitting room, but not in a bathroom or shower
room.
Before making the cut out in the worktop ensure that
there is a minimum distance of 55 mm. between the
rear edge of the hob and the wall.
A minimum distance of 100 mm. must be left
between the side edges of the hob and any adjacent
cabinets or walls.
The minimum distance combustible material can be
fitted above the hob in line with the edges of the hob
is 420 mm. If it is fitted below 420 mm. a space of 50
mm. must be allowed from the edges of the hob.
The minimum distance combustible material can be
fitted directly above the hob is 700 mm.
650 mm
420 mm
420 mm
100 mm
50 mm
50 mm
55 mm
600 mm
700 mm
420 mm
100 mm
420 mm
50 mm
55 mm
50 mm
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE GAS HOB
WITHOUT A COOKER HOOD ABOVE
INSTALLATION GUIDANCE INSTRUCTIONS
CLEARANCES REQUIRED
WHEN FITTING THE GAS HOB
WITH A COOKER HOOD ABOVE
FO 0813FO 0812
700 mm