Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

Height:

88 mm.

Weight:

8 Kg.

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical interference.

Ignition HT Spark

 

 

 

 

 

 

 

 

 

 

 

 

Spark Generator

 

Ispra Control's BF 50046 - 230-240V

0.6 YA T 120

Spark Gap

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear Left Burner (semi rapid)

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input

 

 

2.0 kW (6824 BTU/HR)

Rear Right Burner (semi rapid)

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input

 

2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input

3.0 kW Natural Gas (10236 BTU/HR)

Front Right Burner (auxiliary)

 

 

 

 

 

 

2.8 kW L.P.G. (9554 BTU/HR)

Heat Input

 

1.0 kW (3412 BTU/HR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFTYPE

GAS

 

CHARACTERISTICS

 

BURNER

 

 

RAPID

SEMI-RAPID

AUXILIARY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

 

MAX

MIN

MAX

 

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURALGAS

20mbar

 

=VALUE37.78 MJ/m3 50.7-WsMJ/ m

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

POWER

kW

 

3.0

0.65

 

2.0

 

0.45

1.0

0.33

 

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

m3/h

 

0.286

0.057

 

0.190

 

0.038

0.095

0.028

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

 

119

Adjust.

96

 

Adjust.

70

Adjust.

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GASLPG

mbar30/37-28

 

MJ/Kg49.92=VALUE

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

kW

 

2.8

0.65

 

2.0

 

0.45

1.0

0.33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

g/h

 

202

43.5

 

144

 

29

72

21,5

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

 

86

40

 

71

 

32

50

28

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS APPLIANCE: 3

Burner

 

Dia. Tap By-pass

 

Tap colour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

APPLIANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

28

 

Yellow/Red

 

CATEGORY: II2H3+

Semi-rapid

 

32

 

Green/Black

 

APPLIANCE

 

 

 

Rapid

 

40

 

Violet/Black

 

 

 

 

 

 

 

GAS SUPPLY: Natural gas G20 / 20mbar

Aeration adjustment none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12