Electrolux EHG 6762 manual Wiring Diagram, Fault Finding, Preliminary Electrical Systems Check

Models: EHG 6762

1 16
Download 16 pages 24.7 Kb
Page 13
Image 13
Wiring Diagram

Wiring Diagram

N

1

L

2201 Fault FindingPreliminary Electrical Systems CheckManual backgroundManual backgroundManual background

2

3

0

4

2

1.TAPS IGNITOR SWITCHES

2.IGNITOR UNIT

Fault Finding

Preliminary Electrical Systems Check

Brown Blue

Blue

Brown Green Yellow

START

Isolate appliance and carry out:

A:Earth Continuity check.

PLUG (with cover removed)

SOCKET

 

(face view)

Earth Wire

(

)

 

 

Green/Yellow

E (

)

 

 

 

Neutral Wire

 

FUSE

 

 

Blue

 

 

 

 

 

 

 

 

 

N

 

L

NO

YES

Carry out:

Carry out:

 

Electricity supply

 

 

 

 

 

D: Resistance to

 

 

should now be

 

 

 

C: Polarity check.

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring faulty. Rectify any fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 (Ohm), check all earth wires for continuity and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

13

Page 13
Image 13
Electrolux EHG 6762 manual Wiring Diagram, Fault Finding, Preliminary Electrical Systems Check