Electrolux EHG 6762 Instructions for the Installer, Engineers technical data, Overall dimensions

Models: EHG 6762

1 16
Download 16 pages 24.7 Kb
Page 8
Image 8
Instructions for the Installer

Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

580 mm

Depth:

510 mm

Cut out dimensions

Width:

560 mm

Depth:

480 mm

Supply connections

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Ignition HT Spark

Spark Generator Ispra Control's

BF 50046-06

 

230-240V 0.6 VA T 120

Spark Gap

 

Fixed

Rear Left Burner

 

(semi rapid)

Heat Input

 

2.0 kW (6824 BTU/HR)

Front Left Burner

 

(auxiliary)

Heat Input

 

1.0 kW (3412 BTU/HR)

Rear Right Burner

 

(semi rapid)

Heat Input

 

2.0 kW (6824 BTU/HR)

Front Right Burner

 

(rapid)

Heat Input

3.0 kW (10236 BTU/HR)

TYPE OF GAS

Characteristics

BURNER

 

RAPID

SEMI-RAPID

AUXILIARY

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

POSITION

 

MAX

MIN

MAX

MIN

MAX

MIN

 

 

 

 

 

 

 

 

NATURAL GAS

 

VALUE = 37.78 MJ/m3 Ws - 50.7 MJ/ m3

NOMINALTHERMAL

 

 

 

 

 

 

20 mbar

POWER

kW

3.0

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

m3/h

0.286

0.062

0.190

0.043

0.095

0.031

NOZZLEREFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28-30/37 mbar

VALUE = 49.92 MJ/Kg

NOMINAL THERMAL

 

 

 

 

 

 

LPG GAS

POWER

kW

2.8

0.65

2.0

0.45

1.0

0.33

NOMINAL FLOW

 

 

 

 

 

 

 

RATE

g/h

202

47

144

32

72

24

NOZZLEREFERENCE

86

40

71

32

50

28

1/100 mm

 

 

 

 

 

 

 

Burner

Dia. Tap By-pass

 

1/100 mm

 

 

Auxiliary

28

Semi-rapid

32

Rapid

40

APPLIANCE CLASS:

3

APPLIANCE CATEGORY:

II2H3+

APPLIANCE GAS SUPPLY:Natural gas G20 / 20mbar

Aeration adjustment none

8

Page 8
Image 8
Electrolux EHG 6762 manual Instructions for the Installer, Engineers technical data, Overall dimensions, Cut out dimensions