12
Ignition HT Spark
Spark Generator Ispra Control's BF 50046 - 230-240V 0.6 YA T 120
Spark Gap Fixed
OVERALL DIMENSIONS
Width: 580 mm.
Depth: 500 mm.
Height: 88 mm.
Weight: 8,5 Kg.
Burner Dia. Tap By-pass Tap colour
1/100 mm
Auxiliary 28 Red/Red
Semi-rapid 32 Blue/Blue
Rapid 40 Black/Black
Aeration adjustment none
Instructions for the Installer
CUT OUT DIMENSIONS
Width: 550 mm.
Depth: 470 mm.
Thickness: 30 mm.
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE m
3
/h 0.286 0.057 0.190 0.038 0.095 0.028
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust.
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33
NOMINAL FLOW
RATE g/h 202 43.5 144 29 72 21,5
NOZZLE REFERENCE 86 40 71 32 50 28
NATURAL GAS
20 mbar TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg
VALUE = 37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
Rear Left Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (rapid)
Heat Input 3.0 kW Natural Gas (10236 BTU/HR)
2.8 kW L.P.G. (9554 BTU/HR)
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with
non rewireable plug fitted with a 3 amp cartridge
fuse.
This appliance complies with the EEC Directive No
89/336, concerning suppression of radio electrical
interference.

Engineer technical data

CLASS APPLIANCE: 3
APPLIANCE
CATEGORY: II2H3+
APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar
Rear Right Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (auxiliary)
Heat Input 1.0 kW (3412 BTU/HR)