Instructions for the Installer
Engineers technical data
Overall dimensions
Width: | 580 mm. |
Depth: | 500 mm. |
Cut out dimensions
Width: | 550 mm. |
Depth: | 470 mm. |
Supply connections
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
Ignition HT Spark |
|
Spark Generator | Ispra Control's BF 50066 - |
| |
Spark Gap | Fixed |
Rear Left Burner | |
Heat Input | 2.0 kW (6824 BTU/HR) |
Front Left Burner (rapid)
Heat Input3.0 kW (10236 BTU/HR) 2.8 kW L.P.G. (9554 BTU/HR)
Rear Right Burner
Heat Input | 2.0 kW (6824 BTU/HR) |
Front Right Burner (auxiliary) | |
Heat Input | 1.0 kW (3412 BTU/HR) |
|
|
| BURNER | RAPID | AUXILIARY | |||||
TYPE OF | Characteristics |
| (large) | (medium) | (small) | |||||
GAS |
|
|
|
|
|
|
|
|
| |
|
| POSITION | MAX | MIN | MAX | MIN | MAX | MIN | ||
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
| 3 |
|
|
|
|
|
|
|
| |
| MJ/m m3 | NOMINALTHERMAL | 3.0 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | ||
NATURAL | POWER(kW) |
|
|
|
|
|
| |||
= 37.78 | 50.7 MJ/ |
|
|
|
|
|
| |||
GAS |
|
|
|
|
|
| ||||
NOMINALFLOW | 0.286 | 0.062 | 0.190 | 0.043 | 0.095 | 0.031 | ||||
20 mbar | ||||||||||
|
|
|
|
|
|
| ||||
| RATE (m3/h) |
|
|
|
|
|
| |||
| VALUE | Ws - |
|
|
|
|
|
| ||
| NOZZLEREFERENCE | 119 | Adjust. | 96 | Adjust. | 70 | Adjust. | |||
| (1/100 mm) |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
| MJ/Kg | NOMINALTHERMAL | 2.8 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | ||
LPG GAS | POWER (kW) |
|
|
|
|
|
| |||
49.92 |
|
|
|
|
|
| ||||
NOMINALFLOW | 202 | 47 | 144 | 32 | 72 | 24 | ||||
mbar | ||||||||||
|
|
|
|
|
|
| ||||
= | RATE (g/h) |
|
|
|
|
|
| |||
|
|
|
|
|
|
| ||||
| VALUE |
|
|
|
|
|
| |||
| NOZZLEREFERENCE | 86 | 40 | 71 | 32 | 50 | 28 | |||
| (1/100 mm) |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
Burner | Dia. Tap |
| 1/100 mm |
Auxiliary | 28 |
32 | |
Rapid | 40 |
Aeration adjustment none
APPLIANCE CLASS: | 3 |
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
9