Electrolux EI30HI55K Ventilation Hood Insert Specifications, Electrolux Major Appliances, N.A

Models: EI30HI55K

1 2
Download 2 pages 48.31 Kb
Page 2
Image 2
Ventilation Hood Insert

Ventilation Hood Insert

EI30HI55K S

30" Ventilation Hood Insert Specifications

Product Weights: Hood Insert – 26 lbs.; Integrated Blower – 11 lbs.

(600 CFM); Remote Blower – 37 lbs. (1200 CFM) / 29 lbs. (600 CFM)

30" Vent Hood Insert requires custom-built enclosure with installation of Integrated Blower Motor System (600 CFM) into upper hood insert’s housing; or optional Remote Blower Motor System (1200 or 600 CFM) in separate location. (For installation details and specifications, refer to Product Installation Guide on web.)

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.81 kW (1200 CFM) /

0.40 kW (600 CFM). (For use on adequately wired 120V, dedicated circuit having 2-wire service with a separate ground wire. Appliance must be grounded for safe operation.)

Amps @ 120 Volts = 7.4 Amps (1200 CFM) / 3.7 Amps (600 CFM)

Always consult local and national electric codes. Check local building codes for installation requirements, as they may vary per locale.

Makeup air systems may be required by local building codes when using ventilation systems greater than specified CFM of air movement. Specified CFM varies per locale.

Custom-built enclosure required, with hood cabinet having 22" min. hood insert depth and 30" width between cabinet opening above cooking surface. Structure and support must be capable of supporting 75 lbs.

Locate hood insert away from strong draft areas.

Minimum installation height allowed from bottom of hood canopy

to cooking surface is 24" for electric and 30" for gas. (NOT more than 36" recommended.)

Vent system MUST terminate outdoors through roof or wall; do NOT terminate into attic or other enclosed area.

Electrolux Major Appliances, N.A.

Exhaust opening has 10" diameter round vent outlet. For installations using 600 CFM Blower Motor System, 6" or 8" round vent system recommended; for 1200 CFM, 10" round should be used. (If smaller round vent system is used, sound level will be louder.)

To provide efficient performance, length of vent system and number of elbows should be kept to minimum. Flexible vent greatly reduces performance and is not recommended.

Use metal vent only – rigid metal vent recommended; plastic or metal foil vent not recommended.

For cold weather installation, additional backdraft damper and thermal break should be installed. Thermal break will minimize conduction of outside temperatures as part of the vent system with damper on cold air side of break, as close as possible to where vent system enters heated portion of house.

Optional Remote Blower Motor System Specifications

Remote Blower installs separately from insert and MUST mount to secure roof, ceiling, wall, floor or new/existing frame construction; spanning studs or mounted to plywood between ceiling joists or roof rafters and may require additional framing. (For installation details and specifications, refer to Typical Venting Installations on this page and Product Installation Guide on web.)

Structure and support MUST be capable of supporting 50 lb. weight.

Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions.

Blower Motor System Options

Integrated Blower Motor System Kit: 600 CFM – (PN # EI06HIPIKS).

Remote Blower Motor System Kits:

1200 CFM – (PN # EI12HIPRKS), 600 CFM – (PN # EI06HIPRKS).

USA 10200 David Taylor Drive Charlotte, NC 28262 1-877-4electrolux (1-877-435-3287) electroluxappliances.com

High standards of quality at Electrolux Home Products, Inc. mean

CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 electroluxappliances.ca

we are constantly working to improve our products. We reserve the right

to change specifications or discontinue models without notice.

EI30HI55K 11/11

© 2011 Electrolux Home Products, Inc.