Installation 7
Location
This Use & Care Guide provides general operating instructions for your model. Use the freezer only as
instructed in this Use & Care Guide. Before starting the freezer, follow these important first steps.
•Choose a place that is near a grounded electrical outlet. Do Not use an extension cord or an adapter plug.
•For most efficient operation, the freezer should be located where surrounding temperatures will not drop below 40°F (5°C) or exceed 110°F (43°C).
•For ease of installation, proper air circulation and electrical connections, refer to the illustration for recommended clearances.
•For dynamic condenser models, do not block the toe grille on the lower front of your freezer. Sufficient air circulation is essential for the proper operation of your freezer.
1 Air Space | 3 Air Space |
1 | 3 |
3/8 | 3 |
3/8 | 3 |
| 1 |
Installation for 17 cu. ft. with dynamic condenser
Installation for 21 cu. ft. without dynamic condenser
NOTE
The exterior walls of the freezer may become quite warm as the compressor works to transfer heat from the inside. Temperatures as much as 30°F warmer than room temperatures can be expected.
Door Opening
NOTE
Leveling
The freezer must have all bottom corners resting firmly on a solid floor. The floor must be strong enough to support a fully loaded freezer. It is VERY IMPORTANT for your freezer to be level in order to function properly. If the freezer is not leveled during installation, the door may be misaligned and not close or seal properly, causing cooling, frost or moisture problems.
If your freezer is placed with the door hinge side against a wall, you may have to allow additional space so the door can be opened wider.
To Level Freezer:
After discarding crating screws and wood base, use a carpenter’s level to level the freezer from front
to back. Adjust the plastic leveling feet in front, 1/2